ArticleAnalytical and bioanalytical chemistry2021
Metabolic profiles of human brain parenchyma and glioma for rapid tissue diagnosis by targeted desorption electrospray ionization mass spectrometry.
Article in Analytical and bioanalytical chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 20 citations in OpenAlex.
- Metabolite ratiomics: Rapid diagnosis and classification of gliomas for intraoperative application during brain surgery.Proceedings of the National Academy of Sciences of the United States of America · 2026Article
- Intraoperative Mass Spectrometry in Oncology: Technologies, Clinical Applications, and Challenges.Molecules (Basel, Switzerland) · 2026Review
- Ambient ionization mass spectrometry in brain cancer diagnosis.Journal of mass spectrometry and advances in the clinical lab · 2025Review
- Detection of IDH mutation in glioma by desorption electrospray ionization (DESI) tandem mass spectrometry.Scientific reports · 2024Article
- Special Issue with Research Topics on "Recent Analysis and Applications of Mass Spectra on Biochemistry".International journal of molecular sciences · 2024Article
- Advances in computational and translational approaches for malignant glioma.Frontiers in physiology · 2023Review
- Advances in the intraoperative delineation of malignant glioma margin.Frontiers in oncology · 2023Review
- High-throughput analysis of tissue microarrays using automated desorption electrospray ionization mass spectrometry.Scientific reports · 2022Article
- In Vivo Absolute Metabolite Quantification Using a Multiplexed ERETIC-RX Array Coil for Whole-Brain MR Spectroscopic Imaging.Journal of magnetic resonance imaging : JMRI · 2022Article
- Applications of ambient ionization mass spectrometry in 2021: An annual review.Analytical science advances · 2022Review
- Rapid, Sensitive, and Versatile: A 5-Year Perspective on Applications of Ambient Ionization Mass Spectrometry in Bioanalytical Science.Mass spectrometry reviewsReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
Desorption electrospray ionization mass spectrometry (DESI-MS) is well suited for intraoperative tissue analysis since it requires little sample preparation and offers rapid and sensitive molecular diagnostics. Currently, intraoperative assessment of the tumor cell percentage of glioma biopsies can be made by measuring a single metabolite, N-acetylaspartate (NAA). The inclusion of additional biomarkers will likely improve the accuracy when distinguishing brain parenchyma from glioma by DESI-MS. To explore this possibility, mass spectra were recorded for extracts from 32 unmodified human brain samples with known pathology. Statistical analysis of data obtained from full-scan and multiple reaction monitoring (MRM) profiles identified discriminatory metabolites, namely gamma-aminobutyric acid (GABA), creatine, glutamic acid, carnitine, and hexane-1,2,3,4,5,6-hexol (abbreviated as hexol), as well as the established biomarker NAA. Brain parenchyma was readily differentiated from glioma based on these metabolites as measured both in full-scan mass spectra and by the intensities of their characteristic MRM transitions. New DESI-MS methods (5 min acquisition using full scans and MS/MS), developed to measure ion abundance ratios among these metabolites, were tested using smears of 29 brain samples. Ion abundance ratios based on signals for GABA, creatine, carnitine, and hexol all had sensitivities > 90%, specificities > 80%, and accuracies > 85%. Prospectively, the implementation of diagnostic ion abundance ratios should strengthen the discriminatory power of individual biomarkers and enhance method robustness against signal fluctuations, resulting in an improved DESI-MS method of glioma diagnosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.