Evidence map›Paper›PMID 34372462›Full record

ArticleSensors (Basel, Switzerland)2021

Dynamic Insulin Basal Needs Estimation and Parameters Adjustment in Type 1 Diabetes.

Jesús Berián, Ignacio Bravo, Alfredo Gardel-Vicente, José-Luis Lázaro-Galilea, Mercedes Rigla

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Insulin pumps in children - a systematic review.World journal of clinical pediatrics · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Jesús BeriánCampus Universitario s/n, Polytechnic School, University of Alcala, Alcala de Henares, 28805 Madrid, Spain.ORCID 0000-0002-8735-7357
Ignacio BravoCampus Universitario s/n, Polytechnic School, University of Alcala, Alcala de Henares, 28805 Madrid, Spain.ORCID 0000-0002-6964-0036
Alfredo Gardel-VicenteCampus Universitario s/n, Polytechnic School, University of Alcala, Alcala de Henares, 28805 Madrid, Spain.ORCID 0000-0001-7887-4689
José-Luis Lázaro-GalileaCampus Universitario s/n, Polytechnic School, University of Alcala, Alcala de Henares, 28805 Madrid, Spain.ORCID 0000-0001-5048-7134
Mercedes RiglaCampus Universitario s/n, Polytechnic School, University of Alcala, Alcala de Henares, 28805 Madrid, Spain.ORCID 0000-0002-6691-4871
Universidad de Alcalá · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Technology advances have made possible improvements such as Continuous Glucose Monitors, giving the patient a glucose reading every few minutes, or insulin pumps, allowing more personalized therapies. With the increasing number of available closed-loop systems, new challenges appear regarding algorithms and functionalities. Several of the analysed systems in this paper try to adapt to changes in some patients' conditions and, in several of these systems, other variables such as basal needs are considered fixed from day to day to simplify the control problem. Therefore, these systems require a correct adjustment of the basal needs profile which becomes crucial to obtain good results. In this paper a novel approach tries to dynamically determine the insulin basal needs of the patient and use this information within a closed-loop algorithm, allowing the system to dynamically adjust in situations of illness, exercise, high-fat-content meals or even partially blocked infusion sites and avoiding the need for setting a basal profile that approximately matches the basal needs of the patient. The insulin sensitivity factor and the glycemic target are also dynamically modified according to the situation of the patient. Basal insulin needs are dynamically determined through linear regression via the decomposition of previously dosed insulin and its effect on the patient's glycemia. Using the obtained value as basal insulin needs and other mechanisms such as basal needs modification through its trend, ISF and glycemic targets modification and low-glucose-suspend threshold, the safety of the algorithm is improved. The dynamic basal insulin needs determination was successfully included in a closed-loop control algorithm and was simulated on 30 virtual patients (10 adults, 10 adolescent and 10 children) using an open-source python implementation of the FDA-approved (Food and Drug Administration) UVa (University of Virginia)/Padova Simulator. Simulations showed that the proposed system dynamically determines the basal needs and can adapt to a partial blockage of the insulin infusion, obtaining similar results in terms of time in range to the case in which no blockage was simulated. The proposed algorithm can be incorporated to other current closed-loop control algorithms to directly estimate the patient's basal insulin needs or as a monitoring channel to detect situations in which basal needs may differ from the expected ones.

Indexed as

Diabetes Mellitus, Type 1Pancreas, ArtificialAdolescentAdultAlgorithmsBlood GlucoseBlood Glucose Self-MonitoringChildHumansHypoglycemic AgentsInsulinInsulin Infusion SystemsBlood GlucoseHypoglycemic AgentsInsulinartificial pancreasbasal needsclosed-loopdiabetesinsulin control

Identifiers

PMID34372462
PMCPMC8347968
OpenAlexW3190806774

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.