Evidence map›Paper›PMID 34372396›Full record

ArticleSensors (Basel, Switzerland)2021

Energy and Performance Analysis of Lossless Compression Algorithms for Wireless EMG Sensors.

Giorgio Biagetti, Paolo Crippa, Laura Falaschetti, Ali Mansour, Claudio Turchetti

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. A Review on Assisted Living Using Wearable Devices.Sensors (Basel, Switzerland) · 2024
    Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Giorgio BiagettiDII-Dipartimento di Ingegneria dell'Informazione, Università Politecnica delle Marche, Via Brecce Bianche 12, I-60131 Ancona, Italy.ORCID 0000-0002-6601-0039
Paolo CrippaDII-Dipartimento di Ingegneria dell'Informazione, Università Politecnica delle Marche, Via Brecce Bianche 12, I-60131 Ancona, Italy.ORCID 0000-0003-4504-7550
Laura FalaschettiDII-Dipartimento di Ingegneria dell'Informazione, Università Politecnica delle Marche, Via Brecce Bianche 12, I-60131 Ancona, Italy.ORCID 0000-0003-3183-7682
Ali MansourLab-STICC-Laboratoire des Sciences et Techniques de l'information de la Communication et de la Connaissance, UMR 6285 CNRS, ENSTA Bretagne, 2 Rue F. Verny, 29806 Brest, France.ORCID 0000-0003-4144-8832
Claudio TurchettiDII-Dipartimento di Ingegneria dell'Informazione, Università Politecnica delle Marche, Via Brecce Bianche 12, I-60131 Ancona, Italy.ORCID 0000-0001-8713-9790

Funding

Università Politecnica delle Marche Progetto Stategico di Ateneo 2017
6 · The paper itself

Abstract

Electromyography (EMG) sensors produce a stream of data at rates that can easily saturate a low-energy wireless link such as Bluetooth Low Energy (BLE), especially if more than a few EMG channels are being transmitted simultaneously. Compressing data can thus be seen as a nice feature that could allow both longer battery life and more simultaneous channels at the same time. A lot of research has been done in lossy compression algorithms for EMG data, but being lossy, artifacts are inevitably introduced in the signal. Some artifacts can usually be tolerable for current applications. Nevertheless, for some research purposes and to enable future research on the collected data, that might need to exploit various and currently unforseen features that had been discarded by lossy algorithms, lossless compression of data may be very important, as it guarantees no extra artifacts are introduced on the digitized signal. The present paper aims at demonstrating the effectiveness of such approaches, investigating the performance of several algorithms and their implementation on a real EMG BLE wireless sensor node. It is demonstrated that the required bandwidth can be more than halved, even reduced to 1/4 on an average case, and if the complexity of the compressor is kept low, it also ensures significant power savings.

Indexed as

Data CompressionAlgorithmsArtifactsElectromyographyHumansPhysical PhenomenaSignal Processing, Computer-AssistedBluetooth Low EnergyEMGentropy codingFLAClossless compressionpower optimizationwireless sensors

Identifiers

PMID34372396
PMCPMC8347851

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.