Evidence map›Paper›PMID 34372383›Full record

ArticleSensors (Basel, Switzerland)2021

Comparison of Two Electronic Physical Performance Batteries by Measurement Time and Sarcopenia Classification.

Chan Mi Park, Hee-Won Jung, Il-Young Jang, Ji Yeon Baek, Seongjun Yoon, Hyunchul Roh, Eunju Lee

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Observational
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 2 countries.

Chan Mi ParkAsan Medical Center, Division of Geriatrics, Department of Internal Medicine, University of Ulsan College of Medicine, Seoul 05505, Korea.ORCID 0000-0003-1880-048X
Hee-Won JungAsan Medical Center, Division of Geriatrics, Department of Internal Medicine, University of Ulsan College of Medicine, Seoul 05505, Korea.
Il-Young JangAsan Medical Center, Division of Geriatrics, Department of Internal Medicine, University of Ulsan College of Medicine, Seoul 05505, Korea.ORCID 0000-0003-3617-3301
Ji Yeon BaekAsan Medical Center, Division of Geriatrics, Department of Internal Medicine, University of Ulsan College of Medicine, Seoul 05505, Korea.ORCID 0000-0001-7547-8015
Seongjun YoonDyphi Research Institute, Dyphi Inc., Daejeon 34068, Korea.
Hyunchul RohDyphi Research Institute, Dyphi Inc., Daejeon 34068, Korea.
Eunju LeeAsan Medical Center, Division of Geriatrics, Department of Internal Medicine, University of Ulsan College of Medicine, Seoul 05505, Korea.ORCID 0000-0003-4612-0625
Ulsan College · KR

Funding

Korea Health Industry Development Institute HI18C2383
6 · The paper itself

Abstract

The Short Physical Performance Battery (SPPB) is a widely accepted test for measuring lower extremity function in older adults. However, there are concerns regarding the examination time required to conduct a complete SPPB consisting of three components (walking speed, chair rise, and standing balance tests) in clinical settings. We aimed to assess specific examination times for each component of the electronic Short Physical Performance Battery (eSPPB) and compare the ability of the original three-component examinations (eSPPB) and a faster, two-component examination without a balance test (electronic Quick Physical Performance Battery, eQPPB) to classify sarcopenia. The study was a retrospective, cross-sectional study which included 124 ambulatory outpatients who underwent physical performance examination at a geriatric clinic of a tertiary, academic hospital in Seoul, Korea, between December 2020 and March 2021. For eSPPB, we used a toolkit containing sensors and software (Dyphi, Daejeon, Korea) developed to measure standing balance, walking speed, and chair rise test results. Component-specific time stamps were used to log the raw data. Duration of balance examination, 5 times sit-to-stand test (5XSST), and walking speed examination were calculated. Sarcopenia was determined using the 2019 Asian Working Group for Sarcopenia (AWGS) guideline. The median age was 78 years (interquartile range, IQR: 73,82) and 77 subjects (62.1%) were female. The total mean eSPPB test time was 124.8 ± 29.0 s (balance test time 61.8 ± 12.3 s, 49.5%; gait speed test time 34.3 ± 11.9 s, 27.5%; and 5XSST time 28.7 ± 19.1 s, 23.0%). The total mean eQPPB test time was 63.0 ± 25.4 s. Based on the AWGS criteria, 34 (27.4%) patient's results were consistent with sarcopenia. C-statistics for classifying sarcopenia were 0.83 for eSPPB and 0.85 for eQPPB (

Indexed as

SarcopeniaAgedCross-Sectional StudiesElectronicsFemaleGeriatric AssessmentHand StrengthHumansPhysical Functional PerformanceRetrospective Studiesdiagnosisphysical performancesarcopeniasensor

Identifiers

PMID34372383
PMCPMC8347973
OpenAlexW3185777873

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.