Evidence map›Paper›PMID 34365979›Full record

ArticleJournal of medical case reports2021

Intraoperative detection of parathyroid glands by autofluorescence identification using image-based system: report of 15 cases.

Maksym Gorobeiko, Andrii Dinets

Open access · goldAbstract readCase Reports
In one paragraph

Article in Journal of medical case reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
3.6field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. [Clinical application of parathyroid autofluorescence imaging in endoscopic thyroid surgery].Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2023
    Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Maksym GorobeikoDepartment of Surgery, Taras Shevchenko National University of Kyiv, Demiїvska 13, Ukraine, Kyiv, 03039, Ukraine.
Andrii DinetsDepartment of Surgery, Taras Shevchenko National University of Kyiv, Demiїvska 13, Ukraine, Kyiv, 03039, Ukraine. andrii.dinets@gmail.com.ORCID http://orcid.org/0000-0001-9680-7519
Taras Shevchenko National University of Kyiv · UA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA detection of parathyroid glands by the evaluation of their autofluorescence in the near-infrared spectrum is considered as a promising tool in addition to their visual verification. The aim of this study was to evaluate the role of near-infrared autofluorescence application by using two different image-based systems for the identification of parathyroid glands during surgery of thyroid and parathyroid benign and malignant lesions.

methodsEvaluation of near-infrared autofluorescence was performed in 15 patients by using two different image-based systems equipped with a near-infrared laser camera. Intravenous injection of fluorophore indocyanine green was used for the enhancement of near-infrared autofluorescence signal.

resultsNormal parathyroid glands were identified and mobilized after visual inspection in 12 (80%) patients, which was confirmed by near-infrared autofluorescence evaluation. Confident recognition of parathyroid glands by near-infrared autofluorescence signal and their subsequent distinction from lymph nodes was achieved in two (13%) patients with prior surgery for papillary thyroid carcinoma. In one (7%) case, parathyroid gland was identified as fragments of tissue within the postoperative scarring area by near-infrared autofluorescence evaluation, but not by visual inspection. A less intensive near-infrared autofluorescence signal was detected in the parathyroid gland owing to unintentional excision in one (7%) case. Better signal intensity from parathyroid glands was noticed after changes of the near-infrared camera in Fluobeam 800 image-based system in position to an angle of approximately 45-65° in relation to area of interest in all cases as compared with holding straight on the parathyroid gland. Fluobeam LX demonstrated a good near-infrared autofluorescence signal without any specific changes in the camera angle. Thyroid carcinoma demonstrated low-intensity signal in the case of invasion to thyroid capsule. No fluorescent signal was identified from metastatic, or from normal, lymph nodes.

conclusionsThe application of near-infrared autofluorescence imaging is considered as a useful, but additional, tool for the visual assessment of parathyroid gland in the case of primary neck exploration. The utility of near-infrared autofluorescence imaging for parathyroid detection is increased in the case of repeated surgical intervention owing to increased risk of unintentional parathyroid removal as well as for discrimination of parathyroids from the lymph nodes in cases of thyroid malignancy.

Indexed as

Parathyroid GlandsThyroid NeoplasmsHumansOptical ImagingThyroidectomyCase reportHypoparathyroidismNear-infrared fluorescenceParathyroid autofluorescenceParathyroid identification

Identifiers

PMID34365979
PMCPMC8351090
OpenAlexW3190724795

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.