Evidence map›Paper›PMID 34365499›Full record

ReviewAnnals of work exposures and health2022

Evaluating the Theoretical Background of STOFFENMANAGER® and the Advanced REACH Tool.

Antti Joonas Koivisto, Michael Jayjock, Kaarle J Hämeri, Markku Kulmala, Patrick Van Sprang, Mingzhou Yu, Brandon E Boor, Tareq Hussein, Ismo K Koponen, Jakob Löndahl and 3 more

Abstract readReview
In one paragraph

Review in Annals of work exposures and health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

13 authors.

Antti Joonas KoivistoARCHE Consulting, Liefkensstraat 35D, B-9032 Wondelgem, Belgium.ORCID 0000-0002-6769-1999
Michael JayjockJayjock Associates, LLC, Langhorne, PA, USA.
Kaarle J HämeriInstitute for Atmospheric and Earth System Research (INAR), University of Helsinki, PL 64, FI-00014 UHEL, Helsinki, Finland.
Markku KulmalaInstitute for Atmospheric and Earth System Research (INAR), University of Helsinki, PL 64, FI-00014 UHEL, Helsinki, Finland.
Patrick Van SprangARCHE Consulting, Liefkensstraat 35D, B-9032 Wondelgem, Belgium.
Mingzhou YuLaboratory of Aerosol Science and Technology, China Jiliang University, Hangzhou, China.
Brandon E BoorLyles School of Civil Engineering, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN 47907, USA.ORCID 0000-0003-1011-4100
Tareq HusseinInstitute for Atmospheric and Earth System Research (INAR), University of Helsinki, PL 64, FI-00014 UHEL, Helsinki, Finland.
Ismo K KoponenFORCE Technology, Copenhagen, Denmark.
Jakob LöndahlDivision of Ergonomics and Aerosol Technology, Lund University, PO Box 118, SE-221 00 Lund, Sweden.
Lidia MorawskaInternational Laboratory for Air Quality and Health, Queensland University of Technology, Brisbane, QLD 4001, Australia.
John C LittleDepartment of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA 24060, USA.
Susan ArnoldUniversity of Minnesota Twin Cities, Environmental Health Sciences, School of Public Health, 420 Delaware St SE, Minneapolis, MN, USA.ORCID 0000-0002-1465-3761

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STOFFENMANAGER® and the Advanced REACH Tool (ART) are recommended tools by the European Chemical Agency for regulatory chemical safety assessment. The models are widely used and accepted within the scientific community. STOFFENMANAGER® alone has more than 37 000 users globally and more than 310 000 risk assessment have been carried out by 2020. Regardless of their widespread use, this is the first study evaluating the theoretical backgrounds of each model. STOFFENMANAGER® and ART are based on a modified multiplicative model where an exposure base level (mg m-3) is replaced with a dimensionless intrinsic emission score and the exposure modifying factors are replaced with multipliers that are mainly based on subjective categories that are selected by using exposure taxonomy. The intrinsic emission is a unit of concentration to the substance emission potential that represents the concentration generated in a standardized task without local ventilation. Further information or scientific justification for this selection is not provided. The multipliers have mainly discrete values given in natural logarithm steps (…, 0.3, 1, 3, …) that are allocated by expert judgements. The multipliers scientific reasoning or link to physical quantities is not reported. The models calculate a subjective exposure score, which is then translated to an exposure level (mg m-3) by using a calibration factor. The calibration factor is assigned by comparing the measured personal exposure levels with the exposure score that is calculated for the respective exposure scenarios. A mixed effect regression model was used to calculate correlation factors for four exposure group [e.g. dusts, vapors, mists (low-volatiles), and solid object/abrasion] by using ~1000 measurements for STOFFENMANAGER® and 3000 measurements for ART. The measurement data for calibration are collected from different exposure groups. For example, for dusts the calibration data were pooled from exposure measurements sampled from pharmacies, bakeries, construction industry, and so on, which violates the empirical model basic principles. The calibration databases are not publicly available and thus their quality or subjective selections cannot be evaluated. STOFFENMANAGER® and ART can be classified as subjective categorization tools providing qualitative values as their outputs. By definition, STOFFENMANAGER® and ART cannot be classified as mechanistic models or empirical models. This modeling algorithm does not reflect the physical concept originally presented for the STOFFENMANAGER® and ART. A literature review showed that the models have been validated only at the 'operational analysis' level that describes the model usability. This review revealed that the accuracy of STOFFENMANAGER® is in the range of 100 000 and for ART 100. Calibration and validation studies have shown that typical log-transformed predicted exposure concentration and measured exposure levels often exhibit weak Pearson's correlations (r is <0.6) for both STOFFENMANAGER® and ART. Based on these limitations and performance departure from regulatory criteria for risk assessment models, it is recommended that STOFFENMANAGER® and ART regulatory acceptance for chemical safety decision making should be explicitly qualified as to their current deficiencies.

Indexed as

Occupational ExposureAlgorithmsEnvironmental MonitoringHumansRisk AssessmentVentilationAdvanced REACH Tool (ART)model evaluationoccupational exposure modelsperformanceREACHregulatory acceptanceSTOFFENMANAGER®validation

Identifiers

PMID34365499
PMCPMC9030124

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.