Evidence map›Paper›PMID 34363957›Full record

ArticleNeuroImage2021

Face-selective responses in combined EEG/MEG recordings with fast periodic visual stimulation (FPVS).

O Hauk, G E Rice, A Volfart, F Magnabosco, M A Lambon Ralph, B Rossion

Abstract read
In one paragraph

Article in NeuroImage, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Frequency-tagged EEG reveals category-selective responses to face race.Social cognitive and affective neuroscience · 2026
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

O HaukMRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge CB2 7EF, UK. Electronic address: olaf.hauk@mrc-cbu.cam.ac.uk.
G E RiceMRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge CB2 7EF, UK.
A VolfartUniversité de Lorraine, CNRS, CRAN UMR 7039, Nancy F-54000, France; Research Institute for Psychological Science, University of Louvain, Louvain-la-Neuve, Belgium.
F MagnaboscoMRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge CB2 7EF, UK.
M A Lambon RalphMRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge CB2 7EF, UK.
B RossionUniversité de Lorraine, CNRS, CRAN UMR 7039, Nancy F-54000, France; Université de Lorraine, CHRU-Nancy, Service de Neurologie, Nancy F-54000, France.

Funding

Medical Research Council MC_UU_00005/14Medical Research Council MC_UU_00005/18Medical Research Council MR/R023883/1
6 · The paper itself

Abstract

Fast periodic visual stimulation (FPVS) allows the recording of objective brain responses of human face categorization (i.e., generalizable face-selective responses) with high signal-to-noise ratio. This approach has been successfully employed in a number of scalp electroencephalography (EEG) studies but has not been used with magnetoencephalography (MEG) yet, let alone with combined MEG/EEG recordings and distributed source estimation. Here, we presented various natural images of faces periodically (1.2 Hz) among natural images of objects (base frequency 6 Hz) whilst recording simultaneous EEG and MEG in 15 participants. Both measurement modalities showed face-selective responses at 1.2 Hz and harmonics across participants, with high and comparable signal-to-noise ratio (SNR) in about 3 min of stimulation. The correlation of face categorization responses between EEG and two MEG sensor types was lower than between the two MEG sensor types, indicating that the two sensor modalities provide independent information about the sources of face-selective responses. Face-selective EEG responses were right-lateralized as reported previously, and were numerically but non-significantly right-lateralized in MEG data. Distributed source estimation based on combined EEG/MEG signals confirmed a more bilateral face-selective response in visual brain regions located anteriorly to the common response to all stimuli at 6 Hz and harmonics. Conventional sensor and source space analyses of evoked responses in the time domain further corroborated this result. Our results demonstrate that FPVS in combination with simultaneously recorded EEG and MEG may serve as an efficient localizer paradigm for human face categorization.

Indexed as

AdultBrainBrain MappingElectroencephalographyFacial RecognitionFemaleHumansMagnetoencephalographyMalePattern Recognition, VisualPhotic StimulationSignal-To-Noise RatioYoung AdultElectroencephalographyFace categorizationFace recognitionFrequency taggingMagnetoencephalographySource estimation

Identifiers

PMID34363957
PMCPMC8463833

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.