Evidence map›Paper›PMID 34363576›Full record

ReviewMedical & biological engineering & computing2021

The advances of topology optimization techniques in orthopedic implants: A review.

Naichao Wu, Shan Li, Boyan Zhang, Chenyu Wang, Bingpeng Chen, Qing Han, Jincheng Wang

Abstract readReview
PubMed Publisher
In one paragraph

Review in Medical & biological engineering & computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
6.3field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 70 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Review
  9. Review
  10. [Research progress on the design of bone scaffolds with different single cell structures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2023
    Review
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Naichao WuDepartment of Orthopedics, Second Hospital of Jilin University, Changchun, 130041, China.
Shan LiDermatological Department, Second Hospital of Jilin University, Changchun, 130041, China.
Boyan ZhangDepartment of Orthopedics, Second Hospital of Jilin University, Changchun, 130041, China.
Chenyu WangDepartment of Orthopedics, Second Hospital of Jilin University, Changchun, 130041, China.
Bingpeng ChenDepartment of Orthopedics, Second Hospital of Jilin University, Changchun, 130041, China.
Qing HanDepartment of Orthopedics, Second Hospital of Jilin University, Changchun, 130041, China. my.hanqing@163.com.
Jincheng WangDepartment of Orthopedics, Second Hospital of Jilin University, Changchun, 130041, China. jinchengwang@hotmail.com.
Second Affiliated Hospital of Jilin University · CN

Funding

Bethune plan of Jilin University 470110000692Department of Finance of Jilin Province 201817294302Department of Finance of Jilin Province 2019SCZT046Department of Finance of Jilin Province 2020SCZT037Department of Science and Technology of Jilin Province 20200201453JCDepartment of Science and Technology of Jilin Province, P.R.C 20200403086SFDepartment of Science and Technology of Jilin Province, P.R.C 20200404202YYJilin Province Development and Reform Commission 2018C010Key training plan for outstanding young teachers of Jilin University 419080520253National Key R&D Program of China 2018YFB1105100National Natural Science Foundation of China 81802174National Natural Science Foundation of China 82072456Undergraduate teaching reform research project of Jilin University 4Z2000610852
6 · The paper itself

Abstract

Metal implants are widely used in the treatment of orthopedic diseases. However, owing to the mismatched elastic modulus of the bone and implants, stress shielding often occurs clinically which can result in failure of the implant or fractures around the implant. Topology optimization (TO) is a technique that can provide more efficient material distribution according to the objective function under the special load and boundary conditions. Several researchers have paid close attention to TO for optimal design of orthopedic implants. Thanks to the development of additive manufacturing (AM), the complex structure of the TO design can be fabricated. This article mainly focuses on the current stage of TO technique with respect to the global layout and hierarchical structure in orthopedic implants. In each aspect, diverse implants in different orthopedic fields related to TO design are discussed. The characteristics of implants, methods of TO, validation methods of the newly designed implants, and limitations of current research have been summarized. The review concludes with future challenges and directions for research. Wang TO design of global layout and local structure of implants in diverse fields of orthopedic.

Indexed as

Prostheses and ImplantsElastic ModulusFinite Element AnalysisStress, MechanicalFinite element analysisGlobal layout structureHierarchical structureOrthopedic implantsTopology optimization

Identifiers

PMID34363576
OpenAlexW3193106523

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.