ArticleEuropean radiology2022
Intra-scan inter-tissue variability can help harmonize radiomics features in CT.
Article in European radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Hunting for signal in the noise: identifying robust CT radiomic features across variable scanning settings.European radiology · 2026Article
- Evaluating Performance of a Deep Learning-based Artificial Intelligence Model for Ovarian Tumor Classification Using a Multicenter CT Dataset.Radiology. Imaging cancer · 2026Article
- A comparative analysis of preclinical computed tomography radiomics using cone-beam and micro-computed tomography scanners.Physics and imaging in radiation oncology · 2024Article
- Delta-radiomics features for predicting the major pathological response to neoadjuvant chemoimmunotherapy in non-small cell lung cancer.European radiology · 2024Article
- Robustness of radiomics features of virtual unenhanced and virtual monoenergetic images in dual-energy CT among different imaging platforms and potential role of CT number variability.Insights into imaging · 2023Article
Corrections and comments
- Erratum issued
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveWe studied the repeatability and the relative intra-scan variability across acquisition protocols in CT using phantom and unenhanced abdominal series.
methodsWe used 17 CT scans from the Credence Cartridge Radiomics Phantom database and 20 unenhanced multi-site non-pathologic abdominal patient series for which we measured spleen and liver tissues. We performed multiple measurements in extracting 9 radiomics features. We defined a "tandem" as the measurement of a given tissue (or material) by a given radiomics. For each tandem, we assessed the proportion of the variability attributable to repetitions, acquisition protocols, material, or patient. We analyzed the distribution of the intra-scan correlation between pairs of tandems and checked the impact of correlation coefficient greater than 0.90 in comparing paired and unpaired differences.
resultsThe repeatability of radiomics features depends on the measured material; 56% of tandems were highly repeatable. Histogram-derived radiomics were generally less repeatable. Nearly 60% of relative radiomics measurements had a correlation coefficient higher than 0.90 allowing paired measurements to improve reliability in detecting the difference between two materials. The analysis of liver and spleen tissues showed that measurement variability was negligible with respect to other variabilities. As for phantom data, we found that gray level zone length matrix (GLZLM)-derived radiomics and gray level co-occurrence matrix (GLCM)-derived radiomics were the most correlating features. For these features, relative intra-scan measurements improved the detection of different materials or tissues.
conclusionsWe identified radiomics features for which the intra-scan measurements between tissues are linearly correlated. This property represents an opportunity to improve tissue characterization and inter-site harmonization. KEY POINTS: • The repeatability of radiomics features on CT depends on the measured material or tissue. • Some tandems of radiomics features/tissues are linearly affected by the variability of acquisition protocols on CT. • Relative intra-scan measurements are an opportunity for improving quantitative imaging on CT.