ArticleJournal of the mechanical behavior of biomedical materials2021

Compression of the vascular wall to create a friction fit in a vascular anastomotic coupler.

John Nelson, Dev Patel, Himanshu J Sant, Jill Shea, Bruce K Gale, Jay Agarwal

Open access · greenAbstract read
In one paragraph

Article in Journal of the mechanical behavior of biomedical materials, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

John NelsonDepartment of Biomedical Engineering, College of Engineering, University of Utah, 36 S. Wasatch Drive (SMBB 3100), Salt Lake City, UT 84112, USA.
Dev PatelDepartment of Mechanical Engineering, College of Engineering, University of Utah, 1495 E. 100 S. (1550 MEK), Salt Lake City, UT 84112, USA.
Himanshu J SantDepartment of Mechanical Engineering, College of Engineering, University of Utah, 1495 E. 100 S. (1550 MEK), Salt Lake City, UT 84112, USA.
Jill SheaDepartment of Surgery, University of Utah School of Medicine, 30 N. 1900 E., Salt Lake City, UT 84112, USA.
Bruce K GaleDepartment of Mechanical Engineering, College of Engineering, University of Utah, 1495 E. 100 S. (1550 MEK), Salt Lake City, UT 84112, USA.
Jay AgarwalDivision of Plastic Surgery, Department of Surgery, University of Utah School of Medicine, 30 N. 1900 E. (3B400), Salt Lake City, UT 84112, USA. Electronic address: jay.agarwal@hsc.utah.edu.
University of Utah · US

Funding

A Biodegradable Vascular Coupling Device for End-to-End AnastomosisR44HL132767 · NHLBI · MICROSURGICAL INNOVATIONS, INC. · PI AGARWAL, JAYANT PRASAD, GALE, BRUCE · 2018 to 2019
$1.5M
NHLBI NIH HHS R44 HL132767
6 · The paper itself

Abstract

A previously reported microvascular coupler was shown to effectively create vascular anastomoses, but was too large for practical clinical use. To safely reduce coupler size, certain failure modes needed to be better understood. The coupler functions, in part, by compressing the vessel wall between two concentric rings, creating a friction fit that anchors the device to the vessel. This work investigates the relationship between vessel wall compression and resulting friction fit strength to ensure reducing coupler size will not unduly increase the risk that this friction fit might fail. Vascular walls were compressed to a specified strain and the tensile force required to overcome the resulting friction was measured. Experiments were conducted with various vessel types (Porcine common carotid artery, splenic artery, and jugular vein), across a range of compressive strains (55-95%), and by using either PEEK or HDPE to compress the vessel. Tensile force was increased at a rate of 5 g/min or held constant for 24 h. For experiments with incrementally increasing force, the force at failure varied with compressive strain via a power function. At 70% compression, PEEK produced 4.6 times stronger friction fits than HDPE, and common carotid arteries and splenic arteries produced 1.8 and 1.3 times stronger fits than jugular veins respectively. For experiments where tensile force was applied for 24 h, much lower forces were required to overcome friction. These results were compared to friction fit failure in a coupler prototype and it was found that the prototypes failed at just 30% of the force required to cause vessel slip under the other test conditions. These results were used to develop a model that predicts the probability of device failure via vessel slipping (one design, smaller than previously reported, was estimated to fail at maximum in vivo axial stress once in 500 anastomoses, a potentially safe level of risk).

Indexed as

Jugular VeinsMechanical PhenomenaAnastomosis, SurgicalAnimalsFrictionPressureSwineCompressionFriction fitVascular anastomosisVascular wall

Identifiers

PMID34362677
PMCPMC8440453
OpenAlexW3179105530

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.