Evidence map›Paper›PMID 34362396›Full record

ArticleRadiation oncology (London, England)2021

Applications of various range shifters for proton pencil beam scanning radiotherapy.

Haibo Lin, Chengyu Shi, Sheng Huang, Jiajian Shen, Minglei Kang, Qing Chen, Huifang Zhai, James McDonough, Zelig Tochner, Curtiland Deville and 2 more

Open access · goldAbstract read
In one paragraph

Article in Radiation oncology (London, England), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. ACR-ARS Practice Parameter for the Performance of Proton Beam Therapy.International journal of particle therapy · 2024
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 5 institutions in 2 countries.

Haibo LinNew York Proton Center, New York, 10035, USA. hlin@nyproton.com.ORCID http://orcid.org/0000-0001-7476-0967
Chengyu ShiNew York Proton Center, New York, 10035, USA.
Sheng HuangNew York Proton Center, New York, 10035, USA.
Jiajian ShenMayo Clinic, Phoenix, AZ, 85054, USA.
Minglei KangNew York Proton Center, New York, 10035, USA.
Qing ChenNew York Proton Center, New York, 10035, USA.
Huifang ZhaiNew York Proton Center, New York, 10035, USA.
James McDonoughDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, 19104, USA.
Zelig TochnerDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, 19104, USA.
Curtiland DevilleDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, 21231, USA.
Charles B SimoneNew York Proton Center, New York, 10035, USA.
Stefan BothDepartment of Radiation Oncology, University Medical Center Groningen, Groningen, 9713 GZ, Netherlands.
New York Proton Center · USUniversity of Pennsylvania · USJohns Hopkins University · USMayo Clinic Hospital · USUniversity Medical Center Groningen · NL

Funding

U.S. Department of Defense W81XWH-04-2-0022
6 · The paper itself

Abstract

backgroundA range pull-back device, such as a machine-related range shifter (MRS) or a universal patient-related range shifter (UPRS), is needed in pencil beam scanning technique to treat shallow tumors.

methodsThree UPRS made by QFix (Avondale, PA, USA) allow treating targets across the body: U-shaped bolus (UB), anterior lateral bolus (ALB), and couch top bolus. Head-and-neck (HN) patients who used the UPRS were tested. The in-air spot sizes were measured and compared in this study at air gaps: 6 cm, 16 cm, and 26 cm. Measurements were performed in a solid water phantom using a single-field optimization pencil beam scanning field with the ALB placed at 0, 10, and 20 cm air gaps. The two-dimensional dose maps at the middle of the spread-out Bragg peak were measured using ion chamber array MatriXX PT (IBA-Dosimetry, Schwarzenbruck, Germany) located at isocenter and compared with the treatment planning system.

resultsA UPRS can be consistently placed close to the patient and maintains a relatively small spot size resulting in improved dose distributions. However, when a UPRS is non-removable (e.g. thick couch top), the quality of volumetric imaging is degraded due to their high Z material construction, hindering the value of Image-Guided Radiation Therapy (IGRT). Limitations of using UPRS with small air gaps include reduced couch weight limit, potential collision with patient or immobilization devices, and challenges using non-coplanar fields with certain UPRS. Our experience showed the combination of a U-shaped bolus exclusively for an HN target and an MRS as the complimentary device for head-and-neck targets as well as for all other treatment sites may be ideal to preserve the dosimetric advantages of pencil beam scanning proton treatments across the body.

conclusionWe have described how to implement UPRS and MRS for various clinical indications using the PBS technique, and comprehensively reviewed the advantage and disadvantages of UPRS and MRS. We recommend the removable UB only to be employed for the brain and HN treatments while an automated MRS is used for all proton beams that require RS but not convenient or feasible to use UB.

Indexed as

Phantoms, ImagingAlgorithmsFollow-Up StudiesHead and Neck NeoplasmsHumansImage Processing, Computer-AssistedOrgans at RiskPrognosisProton TherapyRadiotherapy DosageRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedBolusPencil beam scanning (PBS)Proton therapyRange shifter

Identifiers

PMID34362396
PMCPMC8344212
OpenAlexW3135551504

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.