Evidence map›Paper›PMID 34357216›Full record

ArticleMicromachines2021

A Three-Dimensional Micromixer Using Oblique Embedded Ridges.

Lin Li, Qingde Chen, Guodong Sui, Jing Qian, Chi-Tay Tsai, Xunjia Cheng, Wenwen Jing

Abstract read
In one paragraph

Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lin LiDepartment of Ocean & Mechanical Engineering, Florida Atlantic University, 777 Glades Road, Boca Raton, FL 33431, USA.
Qingde ChenDepartment of Ocean & Mechanical Engineering, Florida Atlantic University, 777 Glades Road, Boca Raton, FL 33431, USA.
Guodong SuiDepartment of Environmental Science and Engineering, Fudan University, Shanghai 200032, China.
Jing QianCollege of the Environment & Ecology, Xiamen University, Xiamen 361102, China.
Chi-Tay TsaiDepartment of Ocean & Mechanical Engineering, Florida Atlantic University, 777 Glades Road, Boca Raton, FL 33431, USA.ORCID 0000-0001-8452-5119
Xunjia ChengDepartment of Medical Microbiology and Parasitology, School of Basic Medical Sciences, Fudan University, Shanghai 200032, China.ORCID 0000-0002-8851-6903
Wenwen JingDepartment of Medical Microbiology and Parasitology, School of Basic Medical Sciences, Fudan University, Shanghai 200032, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A micromixer is one of the most significant components in a microfluidic system. A three-dimensional micromixer was developed with advantages of high efficiency, simple fabrication, easy integration, and ease of mass production. The designed principle is based on the concepts of splitting-recombination and chaotic advection. A numerical model of this micromixer was established to characterize the mixing performance for different parameters. A critical Reynolds number (Re) was obtained from the simulation results. When the Re number is smaller than the critical value, the fluid mixing is mainly dependent on the mechanism of splitting-recombination, therefore, the length of the channel capable of complete mixing (complete mixing length) increases as the Re number increases. When the Re number is larger than the critical value, the fluid mixing is dominated by chaotic advection, and the complete mixing length decreases as the Re number increases. For normal fluids, a complete mixing length of 500 µm can be achieved at a very small Re number of 0.007 and increases to 2400 µm as the Re number increases to the critical value of 4.7. As the Re number keep increasing and passes the critical Re number, the complete mixing length continues to descend to 650 µm at the Re number of 66.7. For hard-to-mix fluids (generally referring to fluids with high viscosity and low diffusion coefficient, which are difficult to mix), even though no evidence of strong chaotic advection is presented in the simulation, the micromixer can still achieve a complete mixing length of 2550 µm. The mixing performance of the micromixer was also verified by experiments. The experimental results showed a consistent trend with the numerical simulation results, which both climb upward when the Re number is around 0.007 (flow rate of 0.03 μm/min) to around 10 (flow rate of 50 μm/min), then descend when the Re number is around 13.3 (flow rate of 60 µm/min).

Indexed as