Evidence map›Paper›PMID 34356702›Full record

ReviewBiosensors2021

Emerging Electrochemical Sensors for Real-Time Detection of Tetracyclines in Milk.

Magdalena R Raykova, Damion K Corrigan, Morag Holdsworth, Fiona L Henriquez, Andrew C Ward

Open access · goldAbstract readReview
In one paragraph

Review in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.2field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 64 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Magdalena R RaykovaCivil and Environmental Engineering, University of Strathclyde, Glasgow G1 1XJ, UK.ORCID 0000-0001-9232-4931
Damion K CorriganBiomedical Engineering, University of Strathclyde, Glasgow G1 1QE, UK.ORCID 0000-0002-4647-7483
Morag HoldsworthGraham's Dairy Family, Bridge of Allan, Stirling, Glasgow FK9 4RW, UK.
Fiona L HenriquezSchool of Health and Life Sciences, University of the West of Scotland, Paisley PA1 2BE, UK.
Andrew C WardCivil and Environmental Engineering, University of Strathclyde, Glasgow G1 1XJ, UK.
University of Strathclyde · GBUniversity of the West of Scotland · GB

Funding

Engineering and Physical Sciences Research Council EP/T517938/1
6 · The paper itself

Abstract

Antimicrobial drug residues in food are strictly controlled and monitored by national laws in most territories. Tetracyclines are a major broad-spectrum antibiotic class, active against a wide range of Gram-positive and Gram-negative bacteria, and they are the leading choice for the treatment of many conditions in veterinary medicine in recent years. In dairy farms, milk from cows being treated with antibiotic drugs, such as tetracyclines, is considered unfit for human consumption. Contamination of the farm bulk tank with milk containing these residues presents a threat to confidence of supply and results in financial losses to farmers and dairy. Real-time monitoring of milk production for antimicrobial residues could reduce this risk and help to minimise the release of residues into the environment where they can cause reservoirs of antimicrobial resistance. In this article, we review the existing literature for the detection of tetracyclines in cow's milk. Firstly, the complex nature of the milk matrix is described, and the test strategies in commercial use are outlined. Following this, emerging biosensors in the low-cost biosensors field are contrasted against each other, focusing upon electrochemical biosensors. Existing commercial tests that identify antimicrobial residues within milk are largely limited to beta-lactam detection, or non-specific detection of microbial inhibition, with tests specific to tetracycline residues less prevalent. Herein, we review a number of emerging electrochemical biosensor detection strategies for tetracyclines, which have the potential to close this gap and address the industry challenges associated with existing tests.

Indexed as

AnimalsAnti-Bacterial AgentsBiosensing TechniquesCattleDairyingDrug ResiduesFemaleGram-Negative BacteriaGram-Positive BacteriaHumansMilkTetracyclineTetracyclinesAnti-Bacterial AgentsTetracyclineTetracyclinesantimicrobial residuesantimicrobial resistancedairyelectrochemical biosensorsmilktetracyclines

Identifiers

PMID34356702
PMCPMC8301834
OpenAlexW3181437329

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked