Evidence map›Paper›PMID 34356700›Full record

ArticleBiosensors2021

Comparative Study of In Situ Techniques to Enlarge Gold Nanoparticles for Highly Sensitive Lateral Flow Immunoassay of SARS-CoV-2.

Vasily G Panferov, Nadezhda A Byzova, Sergey F Biketov, Anatoly V Zherdev, Boris B Dzantiev

Open access · goldAbstract readComparative Study
In one paragraph

Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 25 citations in OpenAlex.

  1. Review
  2. Optical lateral flow assays in early diagnosis of SARS-CoV-2 infection.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2024
    Review
  3. Review
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Vasily G PanferovResearch Center of Biotechnology of the Russian Academy of Sciences, A.N. Bach Institute of Biochemistry, 119071 Moscow, Russia.
Nadezhda A ByzovaResearch Center of Biotechnology of the Russian Academy of Sciences, A.N. Bach Institute of Biochemistry, 119071 Moscow, Russia.
Sergey F BiketovState Research Center for Applied Microbiology & Biotechnology, 142279 Obolensk, Moscow Region, Russia.
Anatoly V ZherdevResearch Center of Biotechnology of the Russian Academy of Sciences, A.N. Bach Institute of Biochemistry, 119071 Moscow, Russia.ORCID 0000-0003-3008-2839
Boris B DzantievResearch Center of Biotechnology of the Russian Academy of Sciences, A.N. Bach Institute of Biochemistry, 119071 Moscow, Russia.ORCID 0000-0003-4008-4918
A N Bach Institute of Biochemistry · RUState Research Center for Applied Microbiology and Biotechnology · RU

Funding

Ministry of Education and Science of the Russian Federation 075-15-2019-1671
6 · The paper itself

Abstract

Three techniques were compared for lowering the limit of detection (LOD) of the lateral flow immunoassay (LFIA) of the receptor-binding domain of severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) based on the post-assay in situ enlargement of Au nanoparticles (Au NPs) on a test strip. Silver enhancement (growth of a silver layer over Au NPs-Au@Ag NPs) and gold enhancement (growth of a gold layer over Au NPs) techniques and the novel technique of galvanic replacement of Ag by Au in Au@Ag NPs causing the formation of Au@Ag-Au NPs were performed. All the enhancements were performed on-site after completion of the conventional LFIA and maintained equipment-free assay. The assays demonstrated lowering of LODs in the following rows: 488 pg/mL (conventional LFIA with Au NPs), 61 pg/mL (silver enhancement), 8 pg/mL (galvanic replacement), and 1 pg/mL (gold enhancement). Using gold enhancement as the optimal technique, the maximal dilution of inactivated SARS-CoV-2-containing samples increased 500 times. The developed LFIA provided highly sensitive and rapid (8 min) point-of-need testing.

Indexed as

Binding SitesCOVID-19Early DiagnosisGoldHumansImmunoassayLimit of DetectionMetal NanoparticlesPoint-of-Care TestingSARS-CoV-2SilverSpike Glycoprotein, CoronavirusGoldSilverSpike Glycoprotein, Coronavirusspike protein, SARS-CoV-2antigen testcoronavirusgalvanic replacementgold enhancementimmunochromatographylimit of detectionpoint-of-care testingreceptor-binding domainsilver enhancementspike protein

Identifiers

PMID34356700
PMCPMC8301938
OpenAlexW3178581925

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.