Evidence map›Paper›PMID 34356698›Full record

ArticleBiosensors2021

Impedimetric and Plasmonic Sensing of Collagen I Using a Half-Antibody-Supported, Au-Modified, Self-Assembled Monolayer System.

Marcin Gwiazda, Sheetal K Bhardwaj, Ewa Kijeńska-Gawrońska, Wojciech Swieszkowski, Unni Sivasankaran, Ajeet Kaushik

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 4 countries.

Marcin GwiazdaFaculty of Materials Science and Engineering, Warsaw University of Technology, 141 Woloska Str., 02-507 Warsaw, Poland.ORCID 0000-0001-8815-8803
Sheetal K BhardwajInstitute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima 10, 10-748 Olsztyn, Poland.
Ewa Kijeńska-GawrońskaFaculty of Materials Science and Engineering, Warsaw University of Technology, 141 Woloska Str., 02-507 Warsaw, Poland.ORCID 0000-0002-2614-2838
Wojciech SwieszkowskiFaculty of Materials Science and Engineering, Warsaw University of Technology, 141 Woloska Str., 02-507 Warsaw, Poland.
Unni SivasankaranInstitute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima 10, 10-748 Olsztyn, Poland.
Ajeet KaushikNanoBioTech Laboratory, Department of Natural Sciences, Florida Polytechnic University, Lakeland, FL 33805, USA.
Warsaw University of Technology · PLInLife Institute of Animal Reproduction and Food Research, Polish Academy of Sciences · PLFlorida Polytechnic University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This research presents an electrochemical immunosensor for collagen I detection using a self-assembled monolayer (SAM) of gold nanoparticles (AuNPs) and covalently immobilized half-reduced monoclonal antibody as a receptor; this allowed for the validation of the collagen I concentration through two different independent methods: electrochemically by Electrochemical Impedance Spectroscopy (EIS), and optically by Surface Plasmon Resonance (SPR). The high unique advantage of the proposed sensor is based on the performance of the stable covalent immobilization of the AuNPs and enzymatically reduced half-IgG collagen I antibodies, which ensured their appropriate orientation onto the sensor's surface, good stability, and sensitivity properties. The detection of collagen type I was performed in a concentration range from 1 to 5 pg/mL. Moreover, SPR was utilized to confirm the immobilization of the monoclonal half-antibodies and sensing of collagen I versus time. Furthermore, EIS experiments revealed a limit of detection (LOD) of 0.38 pg/mL. The selectivity of the performed immunosensor was confirmed by negligible responses for BSA. The performed approach of the immunosensor is a novel, innovative attempt that enables the detection of collagen I with very high sensitivity in the range of pg/mL, which is significantly lower than the commonly used enzyme-linked immunosorbent assay (ELISA).

Indexed as

Dielectric SpectroscopyImmunoassaySurface Plasmon ResonanceAntibodies, ImmobilizedAntibodies, MonoclonalBiosensing TechniquesCollagen Type IElectrodesEnzyme-Linked Immunosorbent AssayGoldLimit of DetectionMetal NanoparticlesAntibodies, ImmobilizedAntibodies, MonoclonalCollagen Type IGold4,4′-thiobisbenzenethiolcollagen type Ielectrochemical impedance spectroscopyhalf antibodymedical diagnostic devicesnanogoldsurface plasmon resonance

Identifiers

PMID34356698
PMCPMC8301786
OpenAlexW3179808693

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.