Evidence map›Paper›PMID 34356501›Full record

ArticleBiology2021

Lung Thermal Ablation: Comparison between an Augmented Reality Computed Tomography (CT) 3D Navigation System (SIRIO) and Standard CT-Guided Technique.

Rosario Francesco Grasso, Flavio Andresciani, Carlo Altomare, Giuseppina Pacella, Gennaro Castiello, Massimiliano Carassiti, Carlo Cosimo Quattrocchi, Eliodoro Faiella, Bruno Beomonte Zobel

Open access · goldAbstract read
In one paragraph

Article in Biology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Rosario Francesco GrassoDepartment of Diagnostic and Interventional Radiology, University Hospital Campus Bio-Medico of Rome, Via Alvaro del Portillo, 200, 00128 Rome, Italy.
Flavio AndrescianiDepartment of Diagnostic and Interventional Radiology, University Hospital Campus Bio-Medico of Rome, Via Alvaro del Portillo, 200, 00128 Rome, Italy.
Carlo AltomareDepartment of Diagnostic and Interventional Radiology, University Hospital Campus Bio-Medico of Rome, Via Alvaro del Portillo, 200, 00128 Rome, Italy.
Giuseppina PacellaDepartment of Diagnostic and Interventional Radiology, University Hospital Campus Bio-Medico of Rome, Via Alvaro del Portillo, 200, 00128 Rome, Italy.
Gennaro CastielloDepartment of Diagnostic and Interventional Radiology, University Hospital Campus Bio-Medico of Rome, Via Alvaro del Portillo, 200, 00128 Rome, Italy.ORCID 0000-0003-3046-313X
Massimiliano CarassitiUnit of Anesthesia, Intensive Care and Pain Management, University Hospital Campus Bio-Medico of Rome, Via Alvaro del Portillo, 200, 00128 Rome, Italy.
Carlo Cosimo QuattrocchiDepartment of Diagnostic and Interventional Radiology, University Hospital Campus Bio-Medico of Rome, Via Alvaro del Portillo, 200, 00128 Rome, Italy.
Eliodoro FaiellaDepartment of Diagnostic and Interventional Radiology, University Hospital Campus Bio-Medico of Rome, Via Alvaro del Portillo, 200, 00128 Rome, Italy.
Bruno Beomonte ZobelDepartment of Diagnostic and Interventional Radiology, University Hospital Campus Bio-Medico of Rome, Via Alvaro del Portillo, 200, 00128 Rome, Italy.ORCID 0000-0001-9227-5535
Università Campus Bio-Medico · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: The aim of this retrospective study is to assess safety and efficacy of lung radiofrequency (RFA) and microwave ablation (MWA) using an augmented reality computed tomography (CT) navigation system (SIRIO) and to compare it with the standard CT-guided technique. (2) Methods: Lung RFA and MWA were performed with an augmented reality CT 3D navigation system (SIRIO) in 52 patients. A comparison was then performed with a group of 49 patients undergoing the standard CT-guided technique. All the procedures were divided into four groups based on the lesion diameter (>2 cm or ≤2 cm), and procedural time, the number of CT scans, radiation dose administered, and complications rate were evaluated. Technical success was defined as the presence of a "ground glass" area completely covering the target lesion at the immediate post-procedural CT. (3) Results: Full technical success was achieved in all treated malignant lesions for all the considered groups. SIRIO-guided lung thermo-ablations (LTA) displayed a significant decrease in the number of CT scans, procedure time, and patients' radiation exposure (

Indexed as

lung ablationmicrowave ablationnavigation systemradiation doseradiofrequency

Identifiers

PMID34356501
PMCPMC8301158
OpenAlexW3181682794

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked