Evidence map›Paper›PMID 34355890›Full record

ArticleAnalytical chemistry2021

Pipelines and Systems for Threshold-Avoiding Quantification of LC-MS/MS Data.

Alejandro Sánchez Brotons, Jonatan O Eriksson, Marcel Kwiatkowski, Justina C Wolters, Ido P Kema, Andrei Barcaru, Folkert Kuipers, Stephan J L Bakker, Rainer Bischoff, Frank Suits and 1 more

Abstract read
In one paragraph

Article in Analytical chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Alejandro Sánchez BrotonsDepartment of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, 9713 AV Groningen, The Netherlands.
Jonatan O ErikssonDepartment of Biomedical Engineering, Lund University, 221 84 Lund, Sweden.
Marcel KwiatkowskiDepartment of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, 9713 AV Groningen, The Netherlands.ORCID 0000-0002-5804-6031
Justina C WoltersDepartment of Pediatrics, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
Ido P KemaDepartment of Laboratory Medicine, University Medical Center Groningen, University of Groningen, 9700 RB Groningen, The Netherlands.ORCID 0000-0003-1166-6169
Andrei BarcaruDepartment of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, 9713 AV Groningen, The Netherlands.
Folkert KuipersDepartment of Pediatrics, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
Stephan J L BakkerDepartment of Internal Medicine, Division of Nephrology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
Rainer BischoffDepartment of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, 9713 AV Groningen, The Netherlands.ORCID 0000-0001-9849-0121
Frank SuitsIBM Research-Australia, Southbank, 3006 Victoria, Australia.
Péter HorvatovichDepartment of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, 9713 AV Groningen, The Netherlands.ORCID 0000-0003-2218-1140

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The accurate processing of complex liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) data from biological samples is a major challenge for metabolomics, proteomics, and related approaches. Here, we present the pipelines and systems for threshold-avoiding quantification (PASTAQ) LC-MS/MS preprocessing toolset, which allows highly accurate quantification of data-dependent acquisition LC-MS/MS datasets. PASTAQ performs compound quantification using single-stage (MS1) data and implements novel algorithms for high-performance and accurate quantification, retention time alignment, feature detection, and linking annotations from multiple identification engines. PASTAQ offers straightforward parameterization and automatic generation of quality control plots for data and preprocessing assessment. This design results in smaller variance when analyzing replicates of proteomes mixed with known ratios and allows the detection of peptides over a larger dynamic concentration range compared to widely used proteomics preprocessing tools. The performance of the pipeline is also demonstrated in a biological human serum dataset for the identification of gender-related proteins.

Indexed as

ProteomicsTandem Mass SpectrometryAlgorithmsChromatography, LiquidHumansPeptidesProteomePeptidesProteome

Identifiers

PMID34355890
PMCPMC8374884

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.