Evidence map›Paper›PMID 34355071›Full record

ArticlePhysics and imaging in radiation oncology2021

The impact of image acquisition time on registration, delineation and image quality for magnetic resonance guided radiotherapy of prostate cancer patients.

M E Nowee, V W J van Pelt, I Walraven, R Simões, C P Liskamp, D M J Lambregts, S Heijmink, E Schaake, U A van der Heide, T M Janssen

Open access · goldAbstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

M E NoweeDepartment of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
V W J van PeltDepartment of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
I WalravenDepartment of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
R SimõesDepartment of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
C P LiskampDepartment of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
D M J LambregtsDepartment of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
S HeijminkDepartment of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
E SchaakeDepartment of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
U A van der HeideDepartment of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
T M JanssenDepartment of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
The Netherlands Cancer Institute · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeMagnetic resonance (MR) guided radiotherapy utilizes MR images for (online) plan adaptation and image guidance. The aim of this study was to investigate the impact of variation in MR acquisition time and scan resolution on image quality, interobserver variation in contouring and interobserver variation in registration. MATERIALS AND

methodsNine patients with prostate cancer were included. Four T2-weighted 3D turbo spin echo (T2w 3D TSE) sequences were acquired with different acquisition times and resolutions. Two radiologists assessed image quality, conspicuity of the capsule, peripheral zone and central gland architecture and motion artefacts on a 5 point scale. Images were delineated by two radiation oncologists and interobserver variation was assessed by the 95% Hausdorff distance. Seven observers registered the MR images on the planning CT. Registrations were compared on systematic offset and interobserver variation.

resultsAcquisition times ranged between 1.3 and 6.3 min. Overall image quality and capsule definition were significantly worse for the MR sequence with an acquisition time of 1.3 min compared to the other sequences. Median 95% Hausdorff distance showed no significant differences in interobserver variation of contouring. Systematic offset and interobserver variation in registration were small (<1 mm) and of no clinical significance.

conclusionsOur results can be used to effectively shorten overall fraction time for online adaptive MR guided radiotherapy by optimising the imaging sequence used for registration. From the sequences studied, a sequence of 3.1 min with anisotropic voxels of 1.2 × 1.2 × 2.4 mm

Indexed as

Image-Guided radiotherapyImage qualityImage registrationMagnetic Resonance ImagingProstate carcinomaTarget delineation

Identifiers

PMID34355071
PMCPMC8325094
OpenAlexW3184035581

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.