Evidence map›Paper›PMID 34354137›Full record

ArticleScientific reports2021

Lung-to-finger circulation time can be measured stably with high reproducibility by simple breath holding method in cardiac patients.

Tomoyuki Tobushi, Takatoshi Kasai, Masayuki Hirose, Kazuhiro Sakai, Manabu Akamatsu, Chizuru Ohsawa, Yasuko Yoshioka, Shoko Suda, Nanako Shiroshita, Ryo Nakamura and 5 more

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Tomoyuki TobushiDepartment of Cardiovascular Medicine, Saiseikai Futsukaichi Hospital, Chikushino, Japan.
Takatoshi KasaiDepartment of Cardiovascular Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan.
Masayuki HiroseCenter for Clinical and Translational Research, Kyushu University Hospital, Fukuoka, Japan.
Kazuhiro SakaiImaging Device Development, Fuji Xerox Co., Ltd., Kanagawa, Japan.
Manabu AkamatsuImaging Device Development, Fuji Xerox Co., Ltd., Kanagawa, Japan.
Chizuru OhsawaImaging Device Development, Fuji Xerox Co., Ltd., Kanagawa, Japan.
Yasuko YoshiokaSleep Apnea Center, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Shoko SudaDepartment of Cardiovascular Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan.
Nanako ShiroshitaCardiovascular Respiratory Sleep Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan.
Ryo NakamuraDepartment of Cardiovascular Medicine, Saiseikai Futsukaichi Hospital, Chikushino, Japan.
Toshiaki KadokamiDepartment of Cardiovascular Medicine, Saiseikai Futsukaichi Hospital, Chikushino, Japan.
Takeshi TohyamaCenter for Clinical and Translational Research, Kyushu University Hospital, Fukuoka, Japan.
Kouta FunakoshiCenter for Clinical and Translational Research, Kyushu University Hospital, Fukuoka, Japan.
Kazuya HosokawaDepartment of Cardiovascular Medicine, Kyushu University Hospital, Fukuoka, Japan.
Shin-Ichi AndoSleep Apnea Center, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. shinando@sleep.med.kyushu-u.ac.jp.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Lung to finger circulation time (LFCT) has been used to estimate cardiac function. We developed a new LFCT measurement device using a laser sensor at fingertip. We measured LFCT by measuring time from re-breathing after 20 s of breath hold to the nadir of the difference of transmitted red light and infrared light, which corresponds to percutaneous oxygen saturation. Fifty patients with heart failure were enrolled. The intrasubject stability of the measurement was assessed by the intraclass correlation coefficient (ICC). The ICC calculated from 44 cases was 0.85 (95% confidence interval: 0.77-0.91), which means to have "Excellent reliability." By measuring twice, at least one clear LFCT value was obtained in 89.1% of patients and the overall measurability was 95.7%. We conducted all LFCT measurements safely. High ICCs were obtained even after dividing patients according to age, cardiac index (CI); 0.85 and 0.84 (≥ 75 or < 75 years group, respectively), 0.81 and 0.84 (N = 26, ≥ or < 2.2 L/min/M

Indexed as

AgedBlood Circulation TimeBreath HoldingFemaleFingersHeart FailureHeart Function TestsHumansLasersLungMaleMiddle AgedPulmonary CirculationReproducibility of ResultsRespiration

Identifiers

PMID34354137
PMCPMC8342428

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.