Evidence map›Paper›PMID 34353005›Full record

ArticleEnvironmental analysis, health and toxicology2021

In vitro acute inhalation toxicity for TiO2 (GST) using 3D human tissue model (EpiAirwayTM).

Seong Yong Jang, Myeong Kyu Park, Jae Min Im, Hae Sung Park, Heung Sik Seo, Hee Ju Park, Sung Soon Nah

Open access · bronzeAbstract read
In one paragraph

Article in Environmental analysis, health and toxicology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. The potential adverse human health effects of metal-containing nanoparticles: a scoping review.Journal of occupational medicine and toxicology (London, England) · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Seong Yong JangHealthcare Research Institute, Korea Testing and Research Institute (KTR), 12-63, Sandan-gil, Hwasun-eup, Hwasun-gun, Jeollanam-do, 58141, Republic of Korea.
Myeong Kyu ParkHealthcare Research Institute, Korea Testing and Research Institute (KTR), 12-63, Sandan-gil, Hwasun-eup, Hwasun-gun, Jeollanam-do, 58141, Republic of Korea.
Jae Min ImHealthcare Research Institute, Korea Testing and Research Institute (KTR), 12-63, Sandan-gil, Hwasun-eup, Hwasun-gun, Jeollanam-do, 58141, Republic of Korea.
Hae Sung ParkHealthcare Research Institute, Korea Testing and Research Institute (KTR), 12-63, Sandan-gil, Hwasun-eup, Hwasun-gun, Jeollanam-do, 58141, Republic of Korea.
Heung Sik SeoHealthcare Research Institute, Korea Testing and Research Institute (KTR), 12-63, Sandan-gil, Hwasun-eup, Hwasun-gun, Jeollanam-do, 58141, Republic of Korea.
Hee Ju ParkResearch Laboratory, Bentech Frontier Co. Ltd., Nanosandan-ro, Nam-myeon, Jangseong, Jeollanam-do, 57248, Republic of Korea.
Sung Soon NahDivision of Environment & Health, Korea Testing & Research Institute, 98, Gyoyukwon-ro, Gwacheon-si, Gyeonggi-do, 13810, Republic of Korea.
Korea Testing & Research Institute · KRVitzro Tech (South Korea) · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The present study was performed to screen in vitro potential acute inhalation toxicity using an EpiAirwayTM tissue model (human tracheal/bronchial tissue) for the nano-sized titanium dioxide, GST manufactured as a photocatalyst through of sludge recycling and to compare with P-25 a commercialized photocatalytic material. According to the protocol provided by in vitro tissue manufacturer, the GST was exposure to the tissue for 3 hours in 450, 500, 650, 850 mg/mL concentration after preliminary dose range finding study and then tissue viability (%, IC75) was calculated using the MTT assay. Besides, the histopathological observation was performed to compare to the MTT assay. As a result of study, IC75 could not be confirmed at 850 mg/mL in both GST and P-25 and the grade was confirmed to be IC75> 600 mg/mL in vitro model tissue category. Therefore, it was considered that the GHS category could be classified as 'No classification' in screening method for potential acute inhalation toxicity. Also, not the morphological effects of epithelial cells in tissue model were observed compared with the vehicle control and histological findings were similar to the results of MTT Viability assay. Based on these results, the potential acute inhalation toxicity for GST produced through sludge recycling using in vitro tissue model inhalation toxicity showed that it could be non-hazardous substance. However, further study (in vivo study, etc.) is thought to be needed to ascertain whether GST is a toxic effect or safe.

Indexed as

Acute inhalation toxicityEpiAirwayTMGSTIC75P-25TiO2

Identifiers

PMID34353005
PMCPMC8598406
OpenAlexW3184135483

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.