Evidence map›Paper›PMID 34347340›Full record

ArticleEnvironmental microbiology2021

Environmental contamination with SARS-CoV-2 in COVID-19 hospitals in Wuhan, China, 2020.

Wei Liu, Dingchen Li, Chaojie Yang, Fangyan Chen, Ruizhong Jia, Leili Jia, Xinyi Xia, Shanhong Fan, Qing Tan, Yuehua Ke and 10 more

Abstract read
In one paragraph

Article in Environmental microbiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Air Change Rate and SARS-CoV-2 Exposure in Hospitals and Residences: A Meta-Analysis.Aerosol science and technology : the journal of the American Association for Aerosol Research · 2024
    Article
  4. Transmission of SARS-CoV-2 in the workplace: Key findings from a rapid review of the literature.Aerosol science and technology : the journal of the American Association for Aerosol Research · 2023
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

20 authors.

Wei Liu *Chinese PLA Center for Disease Control & Prevention, Beijing, China.
Dingchen Li *Chinese PLA Center for Disease Control & Prevention, Beijing, China.ORCID 0000-0003-4369-3700
Chaojie Yang *Chinese PLA Center for Disease Control & Prevention, Beijing, China.
Fangyan Chen *Chinese PLA Center for Disease Control & Prevention, Beijing, China.
Ruizhong JiaChinese PLA Center for Disease Control & Prevention, Beijing, China.
Leili JiaChinese PLA Center for Disease Control & Prevention, Beijing, China.
Xinyi XiaHuoshenshan Hospital, Wuhan, China.
Shanhong FanHuoshenshan Hospital, Wuhan, China.
Qing TanHuoshenshan Hospital, Wuhan, China.
Yuehua KeChinese PLA Center for Disease Control & Prevention, Beijing, China.
Yong ChenChinese PLA Center for Disease Control & Prevention, Beijing, China.
Haifeng LiHuoshenshan Hospital, Wuhan, China.
Linfeng ZhanTaiKang Tongji Hospital, Wuhan, China.
Xiong LiuChinese PLA Center for Disease Control & Prevention, Beijing, China.
Jianping YouTaiKang Tongji Hospital, Wuhan, China.
Xiaolin FuTaiKang Tongji Hospital, Wuhan, China.
Dan LiHubei Maternal and Child Health Hospital (Guanggu District), Wuhan, China.
Lin ZhangHubei Maternal and Child Health Hospital (Guanggu District), Wuhan, China.
Changjun WangChinese PLA Center for Disease Control & Prevention, Beijing, China.
Li HanChinese PLA Center for Disease Control & Prevention, Beijing, China.

Funding

Project of Natural Science Foundation of Liaoning Province 20180550255Scientific Research Project of Chinese PLA Center for Disease Prevention & Control
6 · The paper itself

Abstract

Coronavirus disease 2019 (COVID-19) pandemic has caused high number of infections and deaths of healthcare workers globally. Distribution and possible transmission route of SARS-CoV-2 in hospital environment should be clarified. We herein collected 431 environmental (391 surface and 40 air) samples in the intensive care unit (ICU) and general wards (GWs) of three hospitals in Wuhan, China from February 21 to March 4, 2020, and detected SARS-CoV-2 RNA by real-time quantitative PCR. The viral positive rate in the contaminated areas was 17.8% (28/157), whereas there was no virus detected in the clean areas. Higher positive rate (22/59, 37.3%) was found in ICU than that in GWs (3/63, 4.8%). The surfaces of computer keyboards and mouse in the ICU were the most contaminated (8/10, 80.0%), followed by the ground (6/9, 66.7%) and outer glove (2/5, 40.0%). From 17 air samples in the contaminated areas, only one sample collected at a distance of around 30 cm from the patient was positive. Enhanced surface disinfection and hand hygiene effectively decontaminated the virus from the environment. This finding might help understand the transmission route and contamination risk of SARS-CoV-2 and evaluate the effectiveness of infection prevention and control measures in healthcare facilities.

Indexed as

COVID-19HospitalsHumansPandemicsRNA, ViralSARS-CoV-2RNA, Viral

Identifiers

PMID34347340
PMCPMC8441894

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.