Evidence map›Paper›PMID 34344403›Full record

ArticleRadiation oncology (London, England)2021

Does the protocol-required uniform margin around the CTV adequately account for setup inaccuracies in whole breast irradiation?

Jurui Luo, Zhihai Yin, Zhen Zhang, Xiaomao Guo, Xiaoli Yu, Juanqi Wang

Open access · goldAbstract read
In one paragraph

Article in Radiation oncology (London, England), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 11 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Jurui LuoDepartment of Radiation Oncology, Fudan University Shanghai Cancer Center, 270 DongAn Road, Shanghai, China.
Zhihai YinDepartment of Radiation Oncology, Fudan University Shanghai Cancer Center, 270 DongAn Road, Shanghai, China.
Zhen ZhangDepartment of Radiation Oncology, Fudan University Shanghai Cancer Center, 270 DongAn Road, Shanghai, China.
Xiaomao GuoDepartment of Radiation Oncology, Fudan University Shanghai Cancer Center, 270 DongAn Road, Shanghai, China.
Xiaoli YuDepartment of Radiation Oncology, Fudan University Shanghai Cancer Center, 270 DongAn Road, Shanghai, China. stephanieyxl@hotmail.com.
Juanqi WangDepartment of Radiation Oncology, Fudan University Shanghai Cancer Center, 270 DongAn Road, Shanghai, China. richie2010@163.com.
Fudan University Shanghai Cancer Center · CNShanghai Medical College of Fudan University · CN

Funding

National Natural Science Foundation of China 81872457National Natural Science Foundation of China 81972846
6 · The paper itself

Abstract

purposeTo use cone-beam computed tomography (CBCT) imaging to determine the impacts of patient characteristics on the magnitude of geometric setup errors and obtain patient-specific planning target volume (PTV) margins from the correlated patient characteristics in whole breast irradiation (WBI).

methodsBetween January 2019 and December 2019, a total of 97 patients who underwent breast-conserving surgery, followed by intensity-modulated radiation therapy in WBI, were scanned with pre-treatment CBCT for the first three treatment fractions and weekly for the subsequent fractions. Setup errors in the left-right (LR), superior-inferior (SI) and anterior-posterior (AP) directions were recorded and analyzed with patient characteristics-including age, tumor location, body mass index (BMI), chest circumference (CC) and breast volume (BV)-to examine the predictors for setup errors and obtain specific PTV margins.

resultsA total of 679 CBCT images from 97 patients were acquired for analysis. The mean setup errors for the whole group were 2.32 ± 1.21 mm, 3.71 ± 2.21 mm and 2.75 ± 1.56 mm in the LR, SI and AP directions, respectively. Patients' BMI, CC and BV were moderately associated with setup errors, especially in the SI directions (R = 0.40, 0.43 and 0.22, respectively). Setup errors in the SI directions for patients with BMI > 23.8 kg/m

conclusionsThe magnitude of geometric setup errors was moderately correlated with BMI, CC and BV. It was recommended to set patient-specific PTV margins according to patient characteristics in the absence of daily image-guided treatment setup.

Indexed as

Margins of ExcisionPatient PositioningAdultAgedBreast NeoplasmsCone-Beam Computed TomographyFemaleFollow-Up StudiesHumansImage Processing, Computer-AssistedMiddle AgedOrgans at RiskPrognosisRadiotherapy DosageRadiotherapy, Image-GuidedRadiotherapy, Intensity-ModulatedCone-beam computed tomographyMargin selectionPatient characteristicsSetup errorWhole breast irradiation

Identifiers

PMID34344403
PMCPMC8336062
OpenAlexW3192521658

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.