Evidence map›Paper›PMID 34342092›Full record

ArticleNeurogastroenterology and motility2022

The effect of an air purifier on aerosol generation measurements during clinical motility testing.

Wout Verbeure, Annelies Geeraerts, I-Hsuan Huang, Lien Timmermans, Joran Tóth, Hannelore Geysen, Louise Cools, Florencia Carbone, Jolien Schol, Herman Devriese and 4 more

Open access · bronzeAbstract read
In one paragraph

Article in Neurogastroenterology and motility, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 2 institutions in 2 countries.

Wout VerbeureTranslational Research Center for Gastrointestinal Disorders, KU Leuven, Leuven, Belgium.ORCID 0000-0001-9934-4636
Annelies GeeraertsTranslational Research Center for Gastrointestinal Disorders, KU Leuven, Leuven, Belgium.ORCID 0000-0003-4941-3263
I-Hsuan HuangTranslational Research Center for Gastrointestinal Disorders, KU Leuven, Leuven, Belgium.ORCID 0000-0002-9390-6180
Lien TimmermansNeurogastroenterology and motility, University Hospitals Leuven, Leuven, Belgium.
Joran TóthTranslational Research Center for Gastrointestinal Disorders, KU Leuven, Leuven, Belgium.
Hannelore GeysenTranslational Research Center for Gastrointestinal Disorders, KU Leuven, Leuven, Belgium.ORCID 0000-0001-8960-932X
Louise CoolsTranslational Research Center for Gastrointestinal Disorders, KU Leuven, Leuven, Belgium.
Florencia CarboneTranslational Research Center for Gastrointestinal Disorders, KU Leuven, Leuven, Belgium.ORCID 0000-0003-1790-7904
Jolien ScholTranslational Research Center for Gastrointestinal Disorders, KU Leuven, Leuven, Belgium.ORCID 0000-0003-0537-969X
Herman DevriesePrevention and Environment, University Hospitals Leuven, Leuven, Belgium.
Rico HaesaertsNeurogastroenterology and motility, University Hospitals Leuven, Leuven, Belgium.
Hideki MoriTranslational Research Center for Gastrointestinal Disorders, KU Leuven, Leuven, Belgium.ORCID 0000-0001-8830-4671
Tim VanuytselTranslational Research Center for Gastrointestinal Disorders, KU Leuven, Leuven, Belgium.ORCID 0000-0001-8728-0903
Jan TackTranslational Research Center for Gastrointestinal Disorders, KU Leuven, Leuven, Belgium.ORCID 0000-0002-3206-6704
KU Leuven · BETri-Service General Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAerosol spread is key to interpret the risk of viral contamination during clinical procedures such as esophageal high-resolution manometry (HRM). Installing an air purifier seems a legitimate strategy, but this has recently been questioned.

methodsPatients undergoing an HRM procedure at the Leuven University Hospital were included in this clinical study. All subjects had to wear a surgical mask which was only lowered beneath the nose during the placement and removal of the nasogastric catheter. The number of aerosol particles was measured by a Lasair KEY

resultsThirteen patients underwent a manometry examination. The amount of 0.3 µm-sized particles was unaffected during the whole procedure. The larger particle sizes (1.0; 3.0; 5.0; and 10.0 µm) decreased when the catheter was positioned, but not 0.5 µm. During the HRM measurements itself, these numbers decreased further. Yet, 1 min after catheter removal a significant elevation of particles was seen, which did not recover within 5 min. CONCLUSIONS & INTERFERENCES: Based on this study, there is no evidence that filtration systems reduce aerosol particles properly during a clinical investigation.

Indexed as

Air FiltersCOVID-19AerosolsHumansParticle SizeAerosolsaerosolair purifierCOVID19nasogastric intubation

Identifiers

PMID34342092
PMCPMC8420584
OpenAlexW3191845371

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.