Evidence map›Paper›PMID 34341872›Full record

ArticleJournal of experimental orthopaedics2021

Tendon grafts with preserved muscle demonstrate similar biomechanical properties to tendon grafts stripped of muscular attachments: a biomechanical evaluation in a porcine model.

Luis Fernando Zukanovich Funchal, Diego Costa Astur, André Luiz Almeida Pizzolatti, Arthur Paiva Grimaldi, Andrew Esteban Jimenez, Ari Digiácomo Ocampo Moré, Carlos Rodrigo de Mello Roesler, Moises Cohen

Open access · goldAbstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Luis Fernando Zukanovich FunchalBiomechanical Laboratory From Universidade Federal de Santa Catarina, Hospital Baia Sul, Florianópolis, Brazil.
Diego Costa AsturUniversidade Federal de São Paulo, Hospital Samaritano and Instituto Astur, Av Pacaembu 1024, São Paulo, SP, 01234-000, Brazil. mcastur@yahoo.com.ORCID http://orcid.org/0000-0001-9163-7979
André Luiz Almeida PizzolattiBiomechanical Laboratory From Universidade Federal de Santa Catarina, Florianópolis, Brazil.
Arthur Paiva GrimaldiBiomechanical Laboratory From Universidade Federal de Santa Catarina, Florianópolis, Brazil.
Andrew Esteban JimenezUniversity of Connecticut, Storrs, USA.
Ari Digiácomo Ocampo MoréLaboratório de Engenharia Biomecânica Do Hospital Universitário da UFSC, Florianópolis, Brazil.
Carlos Rodrigo de Mello RoeslerDepartment and Chief From Biomechanical Laboratory, Universidade Federal de Santa Catarina, Florianópolis, Brazil.
Moises CohenOrthoapedic Surgeon From Universidade Federal de São Paulo, São Paulo, Brazil.
Universidade Federal de Santa Catarina · BRHospital Samaritano de São Paulo · BRPolydoro Ernani de São Thiago University Hospital · BRUniversidade Federal de São Paulo · BRUniversity of Connecticut · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purpose(1) To evaluate the biomechanical properties of a porcine flexor digitorum superficialis tendon graft with preserved muscle fibers and (2) to compare these results with the biomechanical properties of a porcine tendon graft after removal of associated muscle.

methodsEighty-two porcine forelegs were dissected and the flexor digitorum superficialis muscle tendons were harvested. The study comprised of two groups: Group 1 (G1), harvested tendon with preserved muscle tissue; and Group 2 (G2), harvested contralateral tendon with removal of all muscle tissue. Tests in both groups were conducted using an electro-mechanical material testing machine (Instron, model 23-5S, Instron Corp., Canton, MA, USA) with a 500 N force transducer. Yield load, stiffness, and maximum load were evaluated and compared between groups.

resultsThe behavior of the autografts during the tests followed the same stretching, deformation, and failure patterns as those observed in human autografts subjected to axial strain. There were no significant differences in the comparison between groups for ultimate load to failure (p = 0.105), stiffness (p = 0.097), and energy (p = 0.761).

conclusionIn this porcine model biomechanical study, using autograft tendon with preserved muscle showed no statistically significant differences for yield load, stiffness, or maximum load compared to autograft tendon without preserved muscle. The preservation of muscle on the autograft tendon did not compromise the mechanical properties of the autograft. LEVEL OF EVIDENCE: Level III Controlled laboratory study.

Indexed as

AutograftBiomechanicalFlexor tendonGraft failureUniaxial tension

Identifiers

PMID34341872
PMCPMC8329107
OpenAlexW3190134730

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked