ArticleQuantitative imaging in medicine and surgery2021
MRI chemical shift artifact produced by center-out radial sampling of k-space: a potential pitfall in clinical diagnosis.
Article in Quantitative imaging in medicine and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 25 citations in OpenAlex.
- Zero echo time MRI with deep learning reconstruction and chemical shift correction for detecting osteolytic myeloma lesions.European radiology experimental · 2026Trial
- Chemical Shift Separated and Compensated Ultra-Short Echo-Time Imaging.Magnetic resonance in medicine · 2026Article
- Fat-suppressed quantitative ultrashort echo time magnetization transfer (UTE-MT) imaging of the knee joint.Magma (New York, N.Y.) · 2026Article
- Noninvasive in vivo imaging of macrophages: understanding tumor microenvironments and delivery of therapeutics.Biomarker research · 2025Review
- UTE MRI technical developments and applications in osteoporosis: a review.Frontiers in endocrinology · 2025Review
- Article
- Bone Biomarkers Based on Magnetic Resonance Imaging.Seminars in musculoskeletal radiology · 2024Review
- Bi-Exponential 3D UTE-T1ρ Relaxation Mapping of Ex Vivo Human Knee Patellar Tendon at 3T.Bioengineering (Basel, Switzerland) · 2024Article
- Ultrashort echo time pulse sequences for visualization of deep peripheral fasciae and epimysium in porcine models with histologic correlations.Quantitative imaging in medicine and surgery · 2023Article
- Making the invisible visible-ultrashort echo time magnetic resonance imaging: Technical developments and applications.Applied physics reviews · 2022Review
- Ultrashort Echo Time Magnetic Resonance Imaging Techniques: Met and Unmet Needs in Musculoskeletal Imaging.Journal of magnetic resonance imaging : JMRI · 2022Review
- Minimizing echo and repetition times in magnetic resonance imaging using a double half-echo k-space acquisition and low-rank reconstruction.NMR in biomedicine · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCenter-out radial sampling of k-space in magnetic resonance imaging employs a different direction for each readout. Off-resonance artifacts (including those produced by chemical shift between water and fat) found with this type of sampling are usually described as blurring, however more specific characterization of these artifacts can be ascertained from the fact that their point spread function is ring-shaped. This produces effects that differ from those seen with Cartesian sampling of k-space. Experiments were designed to demonstrate the origin of these artifacts and a volunteer was imaged to show them.
methodsTwo phantoms containing oil in a syringe and an annulus of oil surrounded by water were scanned with a range of bandwidths from 62.5 down to 4 kHz. In a human volunteer, head, pelvis and spine images were obtained with bandwidths of 62.5 and 4 kHz.
resultsThe two phantoms showed displacement of the oil signal away from the center into the region of the surrounding water. The effect increased as the bandwidth was decreased. In the head of the volunteer, signal from fat in red bone marrow in the skull was displaced centrally and peripherally relative to water within the marrow, and appeared in the region between the skull and the brain, as well as in the surrounding scalp. Displacements of the former type simulated subdural hematomas. Displacement of perivesical fat signal centrally over the wall of the bladder simulated bladder tumor, and displacement of fat signal from red bone marrow in the lumbar spine to the intervertebral discs simulated their cartilaginous endplates.
conclusionsCenter-out radial artifacts are important to recognize on clinical images since they may mimic anatomy and simulate pathology. The article shows how these artifacts originate, includes examples, and describes how the artifacts differ from Cartesian chemical shift artifacts.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.