Evidence map›Paper›PMID 34341741›Full record

ArticleQuantitative imaging in medicine and surgery2021

MRI chemical shift artifact produced by center-out radial sampling of k-space: a potential pitfall in clinical diagnosis.

Mark Bydder, Michael Carl, Graeme M Bydder, Jiang Du

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 25 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Bone Biomarkers Based on Magnetic Resonance Imaging.Seminars in musculoskeletal radiology · 2024
    Review
  8. Article
  9. Article
  10. Review
  11. Review
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 2 countries.

Mark BydderDepartment of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, CA, USA.
Michael CarlGlobal MR Application and Workflow, GE Healthcare, San Diego, CA, USA.
Graeme M BydderDepartment of Radiology, University of California San Diego, San Diego, CA, USA.
Jiang DuDepartment of Radiology, University of California San Diego, San Diego, CA, USA.
GE Global Research (United States) · USThe Christie NHS Foundation Trust · GBUniversity of California, Los Angeles · USUniversity of California, San Diego · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCenter-out radial sampling of k-space in magnetic resonance imaging employs a different direction for each readout. Off-resonance artifacts (including those produced by chemical shift between water and fat) found with this type of sampling are usually described as blurring, however more specific characterization of these artifacts can be ascertained from the fact that their point spread function is ring-shaped. This produces effects that differ from those seen with Cartesian sampling of k-space. Experiments were designed to demonstrate the origin of these artifacts and a volunteer was imaged to show them.

methodsTwo phantoms containing oil in a syringe and an annulus of oil surrounded by water were scanned with a range of bandwidths from 62.5 down to 4 kHz. In a human volunteer, head, pelvis and spine images were obtained with bandwidths of 62.5 and 4 kHz.

resultsThe two phantoms showed displacement of the oil signal away from the center into the region of the surrounding water. The effect increased as the bandwidth was decreased. In the head of the volunteer, signal from fat in red bone marrow in the skull was displaced centrally and peripherally relative to water within the marrow, and appeared in the region between the skull and the brain, as well as in the surrounding scalp. Displacements of the former type simulated subdural hematomas. Displacement of perivesical fat signal centrally over the wall of the bladder simulated bladder tumor, and displacement of fat signal from red bone marrow in the lumbar spine to the intervertebral discs simulated their cartilaginous endplates.

conclusionsCenter-out radial artifacts are important to recognize on clinical images since they may mimic anatomy and simulate pathology. The article shows how these artifacts originate, includes examples, and describes how the artifacts differ from Cartesian chemical shift artifacts.

Indexed as

chemical shift artifactfat imagingmagnetic resonance imagingRadial center-out sampling of k-space

Identifiers

PMID34341741
PMCPMC8245944
OpenAlexW3161915558

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.