Evidence map›Paper›PMID 34340671›Full record

ArticleBMC musculoskeletal disorders2021

Design and analysis of three-dimensional printing of a porous titanium scaffold.

Jiajie Yang, Yaqiang Li, Xiaojian Shi, Meihua Shen, Kaibing Shi, Lingjie Shen, Chunxi Yang

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Jiajie Yang *Nantong Haimen People's Hospital, 1201 Beijing Road, Haimen District, Nantong City, 226100, Jiangsu Province, China.
Yaqiang Li *Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine, 145 Shandong Zhong Lu, Shanghai, 200001, China.
Xiaojian ShiNantong Haimen People's Hospital, 1201 Beijing Road, Haimen District, Nantong City, 226100, Jiangsu Province, China.
Meihua ShenNantong Haimen People's Hospital, 1201 Beijing Road, Haimen District, Nantong City, 226100, Jiangsu Province, China.
Kaibing ShiNantong Haimen People's Hospital, 1201 Beijing Road, Haimen District, Nantong City, 226100, Jiangsu Province, China.
Lingjie ShenNantong Haimen People's Hospital, 1201 Beijing Road, Haimen District, Nantong City, 226100, Jiangsu Province, China.
Chunxi YangRenji Hospital Affiliated to Shanghai Jiaotong University School of Medicine, 145 Shandong Zhong Lu, Shanghai, 200001, China. chunxi_yang@163.com.
Renji Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveMechanic strength, pore morphology and size are key factors for the three-dimensional (3D) printing of porous titanium scaffolds, therefore, developing optimal structure for the 3D printed titanium scaffold to fill bone defects in knee joints is instructive and important.

methodsStructural models of titanium scaffolds with fifteen different pore unit were designed with 3D printing computer software; five different scaffold shapes were designed: imitation diamond-60°, imitation diamond-90°, imitation diamond-120°, regular tetrahedron and regular hexahedron. Each structural shape was evaluated with three pore sizes (400, 600 and 800 μm), and fifteen types of cylindrical models (size: 20 mm; height: 20 mm). Autodesk Inventor software was used to determine the strength and safety of the models by simulating simple strength acting on the knee joints. We analyzed the data and found suitable models for the design of 3D printing of porous titanium scaffolds.

resultsFifteen different types of pore unit structural models were evaluated under positive pressure and lateral pressure; the compressive strength reduced when the pore size increased. Under torsional pressure, the strengths of the imitation diamond structure were similar when the pore size increased, and the strengths of the regular tetrahedron and regular hexahedron structures reduced when the pore size increased. In each case, the compressive strength of the regular hexahedron structure was highest, that of the regular tetrahedron was second highest, and that of the imitation diamond structure was relatively low. Fifteen types of cylindrical models under a set force were evaluated, and the sequence of comprehensive compressive strength, from strong to weak was: regular hexahedron > regular tetrahedron > imitation diamond-120° > imitation diamond-90° > imitation diamond-60°. The compressive strength of cylinder models was higher when the pore size was smaller.

conclusionThe pore size and pore morphology were important factors influencing the compressive strength. The strength of each structure reduced when the pore size (400, 600 and 800 μm) increased. The models of regular hexahedron, regular tetrahedron and imitation diamond-120°appeared to meet the conditions of large pore sizes and high compressive strength.

Indexed as

Printing, Three-DimensionalTitaniumCompressive StrengthHumansPorosityTissue ScaffoldsTitaniumBone defectCompressive strengthMetal scaffoldSafety factorThree-dimensional printingTitanium

Identifiers

PMID34340671
PMCPMC8330076
OpenAlexW3164890973

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked