Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels.

Florian Hagen, Antonia Mair, Michael Bitzer, Hans Bösmüller, Marius Horger

Abstract readComparative Study
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Florian HagenDepartment of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany.ORCID 0000-0002-1215-9428
Antonia MairDepartment of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany.ORCID 0000-0002-7205-2657
Michael BitzerDepartment of Internal Medicine I, University Hospital Tübingen, Tübingen, Germany.
Hans BösmüllerDepartment of Pathology and Neuropathology, University Hospital Tübingen and Eberhard Karls University Tübingen, Tübingen, Germany.
Marius HorgerDepartment of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate the accuracy of fully automated liver volume quantification vs. manual quantification using unenhanced as well as enhanced CT-image data as well as two different radiation dose levels and also two image reconstruction kernels. MATERIAL AND

methodsThe local ethics board gave its approval for retrospective data analysis. Automated liver volume quantification in 300 consecutive livers in 164 male and 103 female oncologic patients (64±12y) performed at our institution (between January 2020 and May 2020) using two different dual-energy helicals: portal-venous phase enhanced, ref. tube current 300mAs (CARE Dose4D) for tube A (100 kV) and ref. 232mAs tube current for tube B (Sn140kV), slice collimation 0.6mm, reconstruction kernel I30f/1, recon. thickness of 0.6mm and 5mm, 80-100 mL iodine contrast agent 350 mg/mL, (flow 2mL/s) and unenhanced ref. tube current 100mAs (CARE Dose4D) for tube A (100 kV) and ref. 77mAs tube current for tube B (Sn140kV), slice collimation 0.6mm (kernel Q40f) were analyzed. The post-processing tool (syngo.CT Liver Analysis) is already FDA-approved. Two resident radiologists with no and 1-year CT-experience performed both the automated measurements independently from each other. Results were compared with those of manual liver volume quantification using the same software which was supervised by a senior radiologist with 30-year CT-experience (ground truth).

resultsIn total, a correlation of 98% was obtained for liver volumetry based on enhanced and unenhanced data sets compared to the manual liver quantification. Radiologist #1 and #2 achieved an inter-reader agreement of 99.8% for manual liver segmentation (p<0.0001). Automated liver volumetry resulted in an overestimation (>5% deviation) of 3.7% for unenhanced CT-image data and 4.0% for contrast-enhanced CT-images. Underestimation (<5%) of liver volume was 2.0% for unenhanced CT-image data and 1.3% for enhanced images after automated liver volumetry. Number and distribution of erroneous volume measurements using either thin or thick slice reconstructions was exactly the same, both for the enhanced as well for the unenhanced image data sets (p> 0.05).

conclusionResults of fully automated liver volume quantification are accurate and comparable with those of manual liver volume quantification and the technique seems to be confident even if unenhanced lower-dose CT image data is used.

Indexed as

LiverRadiation DosageTomography, X-Ray ComputedAdultAgedAutomationContrast MediaFemaleHumansImage Processing, Computer-AssistedLiver NeoplasmsMaleMiddle AgedOrgan SizeRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesContrast Media

Identifiers

PMID34339472
PMCPMC8328340

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.