Evidence map›Paper›PMID 34338058›Full record

ArticleTechnology in cancer research & treatment

Fast MCsquare-Based Independent Dose Verification Platform for Pencil Beam Scanning Proton Therapy.

Chunbo Liu, Meng Wei Ho, Jiyeon Park, Wen Chien Hsi, Xiaoying Liang, Zuofeng Li, Yuntao Song, Hansheng Feng, Yawei Zhang

Abstract read
In one paragraph

Article in Technology in cancer research & treatment. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Chunbo LiuSchool of Physical Sciences, 12652University of Science and Technology of China, Hefei, Anhui, China.
Meng Wei Ho90618University of Florida Health Proton Therapy Institute, Jacksonville, FL, USA.
Jiyeon Park90618University of Florida Health Proton Therapy Institute, Jacksonville, FL, USA.
Wen Chien Hsi90618University of Florida Health Proton Therapy Institute, Jacksonville, FL, USA.
Xiaoying Liang90618University of Florida Health Proton Therapy Institute, Jacksonville, FL, USA.
Zuofeng Li90618University of Florida Health Proton Therapy Institute, Jacksonville, FL, USA.
Yuntao SongSchool of Physical Sciences, 12652University of Science and Technology of China, Hefei, Anhui, China.
Hansheng Feng53040Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, China.
Yawei Zhang90618University of Florida Health Proton Therapy Institute, Jacksonville, FL, USA.ORCID 0000-0001-6436-264X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo commission MCsquare (a multi-cores CPU-based dose calculation engine) for pencil beam scanning (PBS) proton therapy, integrate it into RayStation treatment plan system (TPS) to create a dedicated platform for fast independent dose verification.

methodA MCsquare-based independent dose verification platform (MC2InRS) was developed to realize automatic dose re-calculation for clinical use, including data preparation, dose calculation, 2D/3D gamma analysis. MCsquare was commissioned based on in-air lateral dose profiles, integrated depth dose, and the absolute dose of different beam energies for Proteus

resultsBetween simulation and measurement, the distal range differences at 80% (R80) and 20% (R20) dose levels for each energy were below 0.05 mm, and 0.1 mm, respectively, and the absolute dose differences were below 0.5%. 29 out of 36 QA planes reached a 100% gamma passing rate (GPR) for 2%/2mm criteria, and a minimum of 98.3% gamma was obtained in water phantom between simulation and measurement. For the 15 clinical cases investigated, the average 2D GPR (2%/2mm) was 95.4%, 99.3% for MCsquare vs. measurement, MCsquare vs. TPS, respectively. The average 3D GPR (2%/2mm) was 98.9%, 95.3% for MCsquare vs. TPS in water, and computed tomography (CT), respectively.

conclusionMC2InRS, a fast, independent dose verification platform, has been developed to perform dose verification with high accuracy and efficiency for Pencil Bream Scanning (PBS). Its potential to be applied in routine clinical practice has also been discussed.

Indexed as

Proton TherapyAlgorithmsBrain NeoplasmsComputer SimulationFeasibility StudiesHead and Neck NeoplasmsHumansMalePhantoms, ImagingProstatic NeoplasmsRadiotherapy DosageRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedWaterWaterdose verificationMCsquareMonte Carlo simulationpencil beam scanning

Identifiers

PMID34338058
PMCPMC8326813

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked