Evidence map›Paper›PMID 34336159›Full record

ArticleJournal of healthcare engineering2021

Effect of Interventional Therapy on Iliac Venous Compression Syndrome Evaluated and Diagnosed by Artificial Intelligence Algorithm-Based Ultrasound Images.

Ye Bai, Fei Bo, Wencan Ma, Hongwei Xu, Dawei Liu

Open access · hybridAbstract read
In one paragraph

Article in Journal of healthcare engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 84% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Ye BaiDepartment of Interventional Operating, Chengde City Central Hospital, Chengde 067000, Hebei, China.ORCID 0000-0001-5680-433X
Fei BoDepartment of Ultrasound Diagnosis, Chengde City Central Hospital, Chengde 067000, Hebei, China.ORCID 0000-0001-8476-1146
Wencan MaDepartment of Radiology, Chengde City Central Hospital, Chengde 067000, Hebei, China.ORCID 0000-0002-9422-0017
Hongwei XuDepartment of Radiology, Chengde City Central Hospital, Chengde 067000, Hebei, China.ORCID 0000-0002-1692-713X
Dawei LiuDepartment of Interventional Vascular Surgery, Chengde City Central Hospital, Chengde 067000, Hebei, China.ORCID 0000-0002-9076-6012
Affiliated Hospital of Chengde Medical College · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In order to explore the efficacy of using artificial intelligence (AI) algorithm-based ultrasound images to diagnose iliac vein compression syndrome (IVCS) and assist clinicians in the diagnosis of diseases, the characteristics of vein imaging in patients with IVCS were summarized. After ultrasound image acquisition, the image data were preprocessed to construct a deep learning model to realize the position detection of venous compression and the recognition of benign and malignant lesions. In addition, a dataset was built for model evaluation. The data came from patients with thrombotic chronic venous disease (CVD) and deep vein thrombosis (DVT) in hospital. The image feature group of IVCS extracted by cavity convolution was the artificial intelligence algorithm imaging group, and the ultrasound images were directly taken as the control group without processing. Digital subtraction angiography (DSA) was performed to check the patient's veins one week in advance. Then, the patients were rolled into the AI algorithm imaging group and control group, and the correlation between May-Thurner syndrome (MTS) and AI algorithm imaging was analyzed based on DSA and ultrasound results. Satisfaction of intestinal venous stenosis (or occlusion) or formation of collateral circulation was used as a diagnostic index for MTS. Ultrasound showed that the AI algorithm imaging group had a higher percentage of good treatment effects than that of the control group. The call-up rate of the DMRF-convolutional neural network (CNN), precision, and accuracy were all superior to those of the control group. In addition, the degree of venous swelling of patients in the artificial intelligence algorithm imaging group was weak, the degree of pain relief was high after treatment, and the difference between the artificial intelligence algorithm imaging group and control group was statistically considerable (

Indexed as

May-Thurner SyndromeAlgorithmsArtificial IntelligenceHumansIliac VeinUltrasonography

Identifiers

PMID34336159
PMCPMC8321720
OpenAlexW3184665878

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.