Evidence map›Paper›PMID 34335010›Full record

ArticlePhysics of fluids (Woodbury, N.Y. : 1994)2021

Double masking protection vs. comfort-A quantitative assessment.

Venugopal Arumuru, Sidhartha Sankar Samantaray, Jangyadatta Pasa

Open access · greenAbstract read
In one paragraph

Article in Physics of fluids (Woodbury, N.Y. : 1994), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
2.9field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Venugopal ArumuruApplied Fluids Group, School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar 752050, India.ORCID https://orcid.org/0000-0001-5680-8613
Sidhartha Sankar SamantarayApplied Fluids Group, School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar 752050, India.
Jangyadatta PasaApplied Fluids Group, School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar 752050, India.
Indian Institute of Technology Bhubaneswar · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

COVID-19 has forced humankind to adopt face masks as an integral part of everyday life. This preventive measure is an effective source control technique to curb the spread of COVID-19 and other similar diseases. The virus responsible for causing COVID-19 has undergone several mutations in the recent past, including B.1.1.7, B.1.351, P.1, and N501Y, B.1.617, with a higher infectious rate. These viruses' variants are mainly responsible for the recent spike in COVID-19 cases and associated steep rise in mortality rate worldwide. Under these circumstances, the Center for Disease Control (CDC) and health experts recommend double masking, which mainly includes a surgical mask and a cotton mask for the general public. This combination provides an additional layer of protection and masks fitment to minimize the leakage of droplets expelled during coughing, sneezing, talking, and breathing. This leakage may cause airborne transmission of the virus. In the present study, we report a systematic quantitative unsteady pressure measurement supplement with flow visualization to quantify the effectiveness of a single and double mask. We have also evaluated double masking consisting of a surgical mask and an N-95 mask used by medical professionals. A simple knot improves the surgical mask fitment significantly, and hence, the leakage of droplets is minimized. The leakage of the droplets was reduced to a large extent by using a double mask combination of a two-layer cotton mask over the surgical mask with a knot. The double mask combination of surgical + N-95 and two-layer cotton + N-95 masks showed the most promising results, and no leakage of the droplets is observed in the forward direction. A double mask combination of surgical and N-95 mask offers 8.6% and 5.6% lower mean and peak pressures compared to surgical, and cotton mask. The best results are observed with cotton and N-95 masks with 54.6% and 23% lower mean and peak pressures than surgical and cotton masks; hence, this combination will offer more comfort to the wearer.

Identifiers

PMID34335010
PMCPMC8320463
OpenAlexW3185185452

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.