Evidence map›Paper›PMID 34328427›Full record

Observational studyJournal of medical Internet research2021

A Smart Diaper System Using Bluetooth and Smartphones to Automatically Detect Urination and Volume of Voiding: Prospective Observational Pilot Study in an Acute Care Hospital.

Jae Ho Cho, Jung-Yeon Choi, Nak-Hyun Kim, Yejee Lim, Jung Hun Ohn, Eun Sun Kim, Jiwon Ryu, Jangsun Kim, Yiseob Kim, Sun-Wook Kim and 1 more

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in Journal of medical Internet research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
15.6field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 39 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Textronic Sensors of Hazardous Gaseous Substances.Materials (Basel, Switzerland) · 2025
    Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. End-to-end design of wearable sensors.Nature reviews. Materials · 2022
    Review
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Jae Ho ChoDepartment of Internal Medicine, Seoul National University Bundang Hospital, Gyeonggi-do, Republic of Korea.ORCID 0000-0002-8391-0557
Jung-Yeon ChoiDepartment of Internal Medicine, Seoul National University Bundang Hospital, Gyeonggi-do, Republic of Korea.ORCID 0000-0001-5139-5346
Nak-Hyun KimDepartment of Internal Medicine, Seoul National University Bundang Hospital, Gyeonggi-do, Republic of Korea.ORCID 0000-0003-1134-1364
Yejee LimDepartment of Internal Medicine, Seoul National University Bundang Hospital, Gyeonggi-do, Republic of Korea.ORCID 0000-0002-3540-0202
Jung Hun OhnDepartment of Internal Medicine, Seoul National University Bundang Hospital, Gyeonggi-do, Republic of Korea.ORCID 0000-0001-5415-4505
Eun Sun KimDepartment of Internal Medicine, Seoul National University Bundang Hospital, Gyeonggi-do, Republic of Korea.ORCID 0000-0002-6024-5777
Jiwon RyuDepartment of Internal Medicine, Seoul National University Bundang Hospital, Gyeonggi-do, Republic of Korea.ORCID 0000-0002-2372-8948
Jangsun KimPanoptics Corp, Gyeonggi-do, Republic of Korea.ORCID 0000-0002-6425-4961
Yiseob KimPanoptics Corp, Gyeonggi-do, Republic of Korea.ORCID 0000-0003-3632-902X
Sun-Wook KimDepartment of Internal Medicine, Seoul National University Bundang Hospital, Gyeonggi-do, Republic of Korea.ORCID 0000-0003-1506-7366
Kwang-Il KimDepartment of Internal Medicine, Seoul National University Bundang Hospital, Gyeonggi-do, Republic of Korea.ORCID 0000-0002-6658-047X
Seoul National University Bundang Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCaregivers of patients who wear conventional diapers are required to check for voiding every hour because prolonged wearing of wet diapers causes health problems including diaper dermatitis and urinary tract infections. However, frequent checking is labor intensive and disturbs patients' and caregivers' sleep. Furthermore, assessing patients' urine output with diapers in an acute care setting is difficult. Recently, a smart diaper system with wetness detection technology was developed to solve these issues.

objectiveWe aimed to evaluate the applicability of the smart diaper system for urinary detection, its accuracy in measuring voiding volume, and its effect on incontinence-associated dermatitis (IAD) occurrence in an acute care hospital.

methodsThis prospective, observational, single-arm pilot study was conducted at a single tertiary hospital. We recruited 35 participants aged ≥50 years who were wearing diapers due to incontinence between August and November 2020. When the smart diaper becomes wet, the smart diaper system notifies the caregiver to change the diaper and measures voiding volume automatically. Caregivers were instructed to record the weight of wet diapers on frequency volume charts (FVCs). We determined the voiding detection rate of the smart diaper system and compared the urine volume as automatically calculated by the smart diaper system with the volume recorded on FVCs. Agreement between the two measurements was estimated using a Bland-Altman plot. We also checked for the occurrence or aggravation of IAD and bed sores.

resultsA total of 30 participants completed the protocol and 390 episodes of urination were recorded. There were 108 records (27.7%) on both the FVCs and the smart diaper system, 258 (66.2%) on the FVCs alone, 18 (4.6%) on the smart diaper system alone, and 6 (1.5%) on the FVCs with sensing device lost. The detection rate of the smart diaper system was 32.8% (126/384). When analyzing records concurrently listed in both the FVCs and the smart diaper system, linear regression showed a strong correlation between the two measurements (R

conclusionsThe smart diaper system showed acceptable accuracy for measuring urine volume and it could replace conventional FVCs in acute setting hospitals. Furthermore, the smart diaper system has the potential advantage of preventing IAD development and bed sore worsening. However, the detection rate of the smart diaper system was lower than expected. Detection rate polarization among participants was observed, and improvements in the user interface and convenience are needed for older individuals who are unfamiliar with the smart diaper system.

Indexed as

SmartphoneUrinationHospitalsHumansPilot ProjectsProspective Studiesappdiaper rasheHealthenuresismedical devicemHealthmobile phoneobservationalpilot studyprospectivesensorsmart diapersmartphoneurinary incontinenceurinevoided volume

Identifiers

PMID34328427
PMCPMC8367151
OpenAlexW3166026178

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked