Evidence map›Paper›PMID 34326709›Full record

ArticleIEEE sensors journal2019

Developing a Low-Cost Wearable Personal Exposure Monitor for Studying Respiratory Diseases Using Metal-Oxide Sensors.

Kyle R Mallires, Di Wang, Vishal Varun Tipparaju, Nongjian Tao

Abstract read
In one paragraph

Article in IEEE sensors journal, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Kyle R MalliresSchool for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287 USA, and also with The Biodesign Institute, Arizona State University, Tempe, AZ 85287 USA.
Di WangThe Biodesign Institute, Arizona State University, Tempe, AZ 85287 USA.ORCID 0000-0003-1581-4982
Vishal Varun TipparajuSchool of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 USA, and also with The Biodesign Institute, Arizona State University, Tempe, AZ 85287 USA.
Nongjian TaoSchool of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 USA, and also with The Biodesign Institute, Arizona State University, Tempe, AZ 85287 USA.

Funding

A personal exposure and response monitoring system for pediatric asthma studyU01EB021980 · NIBIB · ARIZONA STATE UNIVERSITY-TEMPE CAMPUS · PI TAO, NONGJIAN · 2015 to 2018
$2.0M
NIBIB NIH HHS U01 EB021980
6 · The paper itself

Abstract

Global industrialization and urbanization have led to increased levels of air pollution. Those with respiratory diseases, such as asthma, are at the highest risk for adverse health effects and reduced quality of life. Studying the relationship between pollutants and symptoms is usually achieved with data from government air quality monitoring stations, but these fail to report the spatial and temporal resolution required to track a person's true exposure, especially when the majority of their time is spent indoors. We develop and build eight wrist-worn wearable devices, weighing only 64 g, to measure known asthma symptom triggers: ozone, total volatile organic compounds, temperature, humidity, and activity level. The devices use commercial off-the-shelf components, costing under $150 each to build. This report focuses on the design, calibration, and testing of the devices. Emphasis is placed on the calibration of a metal-oxide-semiconductor gas sensor for detecting ozone, which is a difficult task because of the large variations in ambient temperature and humidity found when using a wearable device. Examples of testing the devices in four real environments are also discussed: 11 days inside a well-ventilated laboratory, ten days outdoors during the summer, alternating the devices between indoor and outdoor environments to examine their response to quickly changing environments, and a field test where scripted activities are performed for a full day. The work demonstrates a wearable device for environmental health studies and addresses the challenges of existing sensors for real-world applications.

Indexed as

Air qualityasthmacalibrationenvironmental monitoringgas sensormetal oxide semiconductorMOSozonepersonal monitoringvolatile organic compoundswearable device

Identifiers

PMID34326709
PMCPMC8318339

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.