Evidence map›Paper›PMID 34324580›Full record

ArticlePloS one2021

Validity and reliability of a novel monitoring sensor for the quantification of the hitting load in tennis.

Vedran Hadžić, Aleš Germič, Aleš Filipčič

Abstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Development of a low-cost team performance tracking system.BMC sports science, medicine & rehabilitation · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Vedran HadžićFaculty of sport, University of Ljubljana, Ljubljana, Slovenia.ORCID 0000-0002-6918-9994
Aleš GermičFaculty of sport, University of Ljubljana, Ljubljana, Slovenia.
Aleš FilipčičFaculty of sport, University of Ljubljana, Ljubljana, Slovenia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wearable sensor systems are a emerging tools for the evaluation of the sport's activity and can be used to quantify the external workload of the athlete. The main goal of this paper was to evaluate the validity and reliability of the "Armbeep inertial measurement unit" (IMU) sensor both in a closed tennis exercise and in open matchplay. Twentyfour junior tennis players performed a baseline drill and played matches, during which they wore a combined accelerometer and gyroscope sensor. Video footage was concomitantly recorded using a digital video camera. The agreement between the measurements was assessed with the intraclass correlation coefficient (ICC) and the standard error of measurement (SEM). A simple linear regression was used to predict the number of shots registered from the video and from the Armbeep IMU sensor's data. The number of total forehand and backhand shots during the drill repetitions showed an excellent test and re-test reproducibility (ICC≥0.90). There was a significant relationship between the Armbeep IMU sensor's number of contacts and the total number of shots (R2 = 0.938) which indicated the excellent reliability of the tested Armbeep IMU sensor for those parameters. Considering the accuracy of the total tennis shots and the small magnitude of error for wrist speed and acceleration, the Armbeep IMU sensor appears to be an appropriate on-court tool that can be used to monitor the hitting load during tennis practice and matches.

Indexed as

TennisWearable Electronic DevicesAccelerometryAdolescentAthletesAthletic PerformanceBiomechanical PhenomenaFemaleHumansMaleReproducibility of Results

Identifiers

PMID34324580
PMCPMC8321100

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.