Evidence map›Paper›PMID 34324024›Full record

ArticleEuropean radiology2022

Respiratory anomalies associated with gadoxetate disodium and gadoterate meglumine: compressed sensing MRI revealing physiologic phenomena during the entire injection cycle.

Carl Guillaume Glessgen, Hanns-Christian Breit, Tobias Kai Block, Elmar Max Merkle, Tobias Heye, Daniel Tobias Boll

Open access · hybridAbstract read
In one paragraph

Article in European radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Carl Guillaume GlessgenDepartment of Radiology, University Hospital Basel, Basel, Switzerland. carlguillaume.glessgen@usb.ch.ORCID http://orcid.org/0000-0002-9836-7139
Hanns-Christian BreitDepartment of Radiology, University Hospital Basel, Basel, Switzerland.
Tobias Kai BlockCenter for Advanced Imaging Innovation and Research, Department of Radiology, New York University Grossman School of Medicine, New York, USA.
Elmar Max MerkleDepartment of Radiology, University Hospital Basel, Basel, Switzerland.
Tobias HeyeDepartment of Radiology, University Hospital Basel, Basel, Switzerland.
Daniel Tobias BollDepartment of Radiology, University Hospital Basel, Basel, Switzerland.
University Hospital of Basel · CHNew York University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe goal of this study was to investigate the precise timeline of respiratory events occurring after the administration of two gadolinium-based contrast agents, gadoxetate disodium and gadoterate meglumine. MATERIALS AND

methodsThis retrospective study examined 497 patients subject to hepatobiliary imaging using the GRASP MRI technique (TR/TE = 4/2 ms; ST = 2.5 mm; 384 × 384 mm). Imaging was performed after administration of gadoxetate (N = 338) and gadoterate (N = 159). All GRASP datasets were reconstructed using a temporal resolution of 1 s. Four regions-of-interest (ROIs) were placed in the liver dome, the right and left cardiac ventricle, and abdominal aorta detecting liver displacement and increasing vascular signal intensities over time. Changes in hepatic intensity reflected respiratory dynamics in temporal correlation to the vascular contrast bolus.

resultsIn total, 216 (67%) and 41 (28%) patients presented with transient respiratory motion after administration of gadoxetate and gadoterate, respectively. The mean duration from start to acme of the respiratory episode was similar (p = 0.4) between gadoxetate (6.0 s) and gadoterate (5.6 s). Its mean onset in reference to contrast arrival in the right ventricle differed significantly (p < 0.001) between gadoxetate (15.3s) and gadoterate (1.8 s), analogously to peak inspiration timepoint in reference to the aortic enhancement arrival (gadoxetate: 0.9s after, gadoterate: 11.2 s before aortic enhancement, p < 0.001).

conclusionsThe timepoint of occurrence of transient respiratory anomalies associated with gadoxetate disodium and gadoterate meglumine differs significantly between both contrast agents while the duration of the event remains similar. KEY POINTS: • Transient respiratory anomalies following the administration of gadoterate meglumine occurred during a time period usually not acquired in MR imaging. • Transient respiratory anomalies following the administration of gadoxetate disodium occurred around the initiation of arterial phase imaging. • The estimated duration of respiratory events was similar between both contrast agents.

Indexed as

Gadolinium DTPAOrganometallic CompoundsContrast MediaHumansMagnetic Resonance ImagingMeglumineRetrospective StudiesContrast MediaGadolinium DTPAgadolinium ethoxybenzyl DTPAgadoterate meglumineMeglumineOrganometallic CompoundsContrast mediaImage processingLiverRespiratory rate

Identifiers

PMID34324024
PMCPMC8660712
OpenAlexW3185500593

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.