SynthesisLangenbeck's archives of surgery2022

Near-infrared autofluorescence-based parathyroid glands identification in the thyroidectomy or parathyroidectomy: a systematic review and meta-analysis.

Do Hyun Kim, Sunwoo Lee, Jaehoon Jung, Sohyun Kim, Sung Won Kim, Se Hwan Hwang

Abstract readMeta-AnalysisSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Langenbeck's archives of surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
5.4field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 32 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Review
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Do Hyun KimDepartment of Otolaryngology-Head and Neck Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Sunwoo LeeDepartment of Otolaryngology-Head and Neck Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Jaehoon JungDepartment of Otolaryngology-Head and Neck Surgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 327 Sosa-ro, Bucheon-si, Gyeonggi-do, 14647, Korea.
Sohyun KimDepartment of Otolaryngology-Head and Neck Surgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 327 Sosa-ro, Bucheon-si, Gyeonggi-do, 14647, Korea.
Sung Won KimDepartment of Otolaryngology-Head and Neck Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Se Hwan HwangDepartment of Otolaryngology-Head and Neck Surgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 327 Sosa-ro, Bucheon-si, Gyeonggi-do, 14647, Korea. yellobird@catholic.ac.kr.ORCID http://orcid.org/0000-0002-2838-7820
The Catholic University of Korea Bucheon St. Mary's Hospital · KRThe Catholic University of Korea Seoul St. Mary's Hospital · KR

Funding

National Research Foundation of Korea 2018R1D1A1B07045421National Research Foundation of Korea 2019M3A9H2032424, 2019M3E5D5064110National Research Foundation of Korea 2020R1I1A1A01051844
6 · The paper itself

Abstract

purposeTo evaluate the diagnostic accuracy of near-infrared autofluorescence-based identification in the identification of parathyroid glands during thyroidectomy or parathyroidectomy.

methodsThe clinical studies were retrieved from PubMed, the Cochrane Central Register of Controlled Trials, Embase, Web of Science, SCOPUS, and Google Scholar. The study protocol was registered on Open Science Framework ( https://osf.io/um8rj/ ). The search period ranged from the date of each database's inception to May 2021. Cohort studies dealing with patients of whom parathyroid glands were detected by near-infrared autofluorescence and confirmed clinically or pathologically during thyroidectomy or parathyroidectomy were included. Editorials, letters, "how-I-do-it" descriptions, other site head and neck tumors, and articles with lack of diagnostic identification data were excluded. True positive, true negative, false positive, and false negative were extracted. The QUDAS ver. 2 was used to evaluate the methodological quality.

resultsSeventeen studies with 1198 participants were evaluated in this analysis. Near-infrared autofluorescence-based identification of parathyroid glands showed a diagnostic odds ratio of 228.8759 (95% confidence interval, 134.1099; 390.6063). The area under the summary receiver operating characteristic curve was 0.967. The sensitivity, specificity, negative predictive value, and positive predictive value were 0.9693 (0.9491; 0.9816), 0.9248 (0.8885; 0.9499), 0.9517 (0.8981; 0.9778), and 0.9488 (0.9167; 0.9689), respectively. Subgroup analyses were performed to compare two autofluorescence detection methods, because there was high heterogeneity in the outcomes. The diagnostic accuracy was higher in probe-based detection than in image-based detection.

conclusionsNear-infrared autofluorescence-based identification is valuable for identifying the parathyroid glands of patients during thyroidectomy or parathyroidectomy.

Indexed as

ParathyroidectomyParathyroid GlandsCohort StudiesHumansOptical ImagingThyroidectomyFluorescenceOptical imagingParathyroid glandsPredictive value of testsThyroidectomy

Identifiers

PMID34322746
OpenAlexW3186956368

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.