Evidence map›Paper›PMID 34321029›Full record

ArticleRadiation oncology (London, England)2021

Implementation and experimental evaluation of Mega-voltage fan-beam CT using a linear accelerator.

Hao Gong, Shengzhen Tao, Justin D Gagneur, Wei Liu, Jiajian Shen, Cynthia H McCollough, Yanle Hu, Shuai Leng

Abstract read
In one paragraph

Article in Radiation oncology (London, England), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hao GongDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Shengzhen TaoDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Justin D GagneurDepartment of Radiology, Mayo Clinic Arizona, 5881 East Mayo Blvd, Phoenix, AZ, 85258, USA.
Wei LiuDepartment of Radiology, Mayo Clinic Arizona, 5881 East Mayo Blvd, Phoenix, AZ, 85258, USA.
Jiajian ShenDepartment of Radiology, Mayo Clinic Arizona, 5881 East Mayo Blvd, Phoenix, AZ, 85258, USA.
Cynthia H McColloughDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Yanle HuDepartment of Radiology, Mayo Clinic Arizona, 5881 East Mayo Blvd, Phoenix, AZ, 85258, USA. Hu.Yanle@mayo.edu.
Shuai LengDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA. Leng.Shuai@mayo.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMega-voltage fan-beam Computed Tomography (MV-FBCT) holds potential in accurate determination of relative electron density (RED) and proton stopping power ratio (SPR) but is not widely available.

objectiveTo demonstrate the feasibility of MV-FBCT using a medical linear accelerator (LINAC) with a 2.5 MV imaging beam, an electronic portal imaging device (EPID) and multileaf collimators (MLCs).

methodsMLCs were used to collimate MV beam along z direction to enable a 1 cm width fan-beam. Projection data were acquired within one gantry rotation and preprocessed with in-house developed artifact correction algorithms before the reconstruction. MV-FBCT data were acquired at two dose levels: 30 and 60 monitor units (MUs). A Catphan 604 phantom was used to evaluate basic image quality. A head-sized CIRS phantom with three configurations of tissue-mimicking inserts was scanned and MV-FBCT Hounsfield unit (HU) to RED calibration was established for each insert configuration using linear regression. The determination coefficient ([Formula: see text]) was used to gauge the accuracy of HU-RED calibration. Results were compared with baseline single-energy kilo-voltage treatment planning CT (TP-CT) HU-RED calibration which represented the current standard clinical practice.

resultsThe in-house artifact correction algorithms effectively suppressed ring artifact, cupping artifact, and CT number bias in MV-FBCT. Compared to TP-CT, MV-FBCT was able to improve the prediction accuracy of the HU-RED calibration curve for all three configurations of insert materials, with [Formula: see text] > 0.9994 and [Formula: see text] < 0.9990 for MV-FBCT and TP-CT HU-RED calibration curves of soft-tissue inserts, respectively. The measured mean CT numbers of blood-iodine mixture inserts in TP-CT drastically deviated from the fitted values but not in MV-FBCT. Reducing the radiation level from 60 to 30 MU did not decrease the prediction accuracy of the MV-FBCT HU-RED calibration curve.

conclusionWe demonstrated the feasibility of MV-FBCT and its potential in providing more accurate RED estimation.

Indexed as

AlgorithmsPhantoms, ImagingArtifactsCalibrationHumansImage Processing, Computer-AssistedNeoplasmsParticle AcceleratorsRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedDose calculationElectron densityMega-voltage CTRadiation therapy

Identifiers

PMID34321029
PMCPMC8317342

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.