Evidence map›Paper›PMID 34320528›Full record

ArticleEar and hearing

Automated Adaptive Wideband Acoustic Reflex Threshold Estimation in Normal-hearing Adults.

Kim S Schairer, Daniel B Putterman, Douglas H Keefe, Denis Fitzpatrick, Angela Garinis, Elizabeth Kolberg, M Patrick Feeney

Open access · greenAbstract read
In one paragraph

Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.9field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. Rapid Characterization of Middle-Ear Muscle Reflexes Using Swept Elicitors.Journal of the Association for Research in Otolaryngology : JARO · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Wideband Acoustic Reflex Measurement.Seminars in hearing · 2023
    Review
  6. Review
  7. Article
  8. [Characteristics and differential diagnosis of middle ear cholesteatoma and chronic suppurative otitis media with wideband acoustic immittance].Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Kim S SchairerHearing & Balance Research Program James H. Quillen VA Medical Center, Mountain Home, Tennessee.
Daniel B PuttermanVA Portland Health Care System, National Center for Rehabilitative Auditory Research, Portland, Oregon.
Douglas H KeefeBoys Town National Research Hospital, Omaha, Nebraska.
Denis FitzpatrickBoys Town National Research Hospital, Omaha, Nebraska.
Angela GarinisVA Portland Health Care System, National Center for Rehabilitative Auditory Research, Portland, Oregon.
Elizabeth KolbergNeuroscience and Cognitive Science Program, Hearing and Speech Sciences Department, University of Maryland, College Park, Maryland.
M Patrick FeeneyVA Portland Health Care System, National Center for Rehabilitative Auditory Research, Portland, Oregon.
VA Portland Health Care System · USBoys Town National Research Hospital · USEast Tennessee State University · US

Funding

RRD VA I01 RX001268
6 · The paper itself

Abstract

objectivesAcoustic stapedius reflex threshold (ART) tests are included in a standard clinical acoustic immittance test battery as an objective cross-check with behavioral results and to help identify site of lesion. In traditional clinical test batteries, middle-ear admittance of a 226 Hz probe is estimated using ear-canal measurements in the presence of a reflex-activating stimulus. In the wideband (WB) acoustic immittance ART test used in this study, the pure-tone probe is replaced by a WB probe stimulus and changes in absorbed power are estimated using ear-canal measurements in the presence of the activator. The ART is defined as the lowest level at which a criterion change in admittance (clinical) or absorbed power (WB) is observed in the presence of the activator. In the present study, ARTs were obtained in adults with normal hearing using the clinical, manual method and with a new WB automated adaptive threshold detection method. It was hypothesized that the WB test would result in lower ARTs than the clinical test because reflex-related changes in power absorbance could be observed across multiple frequency bands in the WB test compared with a single frequency in the traditional test.

designData were collected in a prospective research design. ARTs were obtained in ipsilateral and contralateral conditions using 500, 1000, 2000 Hz, and broadband noise (BBN) activators on a clinical system and on an experimental WB system. The bandwidth of the BBN activator was 125 to 4000 Hz on the clinical system and 200 to 8000 Hz on the wideband system. ARTs were estimated at both tympanometric peak pressure (TPP) and ambient pressure on the WB system. Data were collected in both ears of 39 adults (21 males) of mean age 47.7 years (range 23-72 years). Differences in ARTs among the three threshold estimation methods (clinical, WB at TPP, WB at ambient) were examined using the general linear model repeated measures test in SPSS. Post-hoc pairwise comparisons were completed with Bonferroni correction for multiple comparisons. Statistical significance was defined as p < 0.05 for all analyses.

resultsARTs obtained on the WB system at TPP and ambient pressure were significantly lower than obtained on the clinical system. ARTs obtained on the WB system at TPP were significantly higher than at ambient pressure in the 500 and 2000 Hz ipsilateral conditions.

conclusionsWB automated adaptive ARTs in normal-hearing adults were lower than for clinical methods when measured at TPP and ambient pressure. Lower presentation levels required to estimate ART in the WB test may be more tolerable to patients. Patients with ARTs that are not present at the maximum level of a traditional reflex test may have present ARTs with a WB ART test, which may reduce the need to refer for additional testing for possible retrocochlear involvement. Automation of the test may allow clinicians more time to attend to the other requisite tasks of a hearing evaluation and make the system useful for telehealth applications.

Indexed as

Acoustic Impedance TestsReflex, AcousticAdultAgedAuditory ThresholdEar, MiddleFemaleHearingHumansMaleMiddle AgedProspective StudiesYoung Adult

Identifiers

PMID34320528
PMCPMC11106794
OpenAlexW3185847448

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.