Observational studyJAMA cardiology2021
Contemporaneous Comparison of Outcomes Among Patients Implanted With a Leadless vs Transvenous Single-Chamber Ventricular Pacemaker.
Observational study in JAMA cardiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 63 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
63 citing papers in PubMed, 3 syntheses or guidelines pooled it, 127 citations in OpenAlex.
- Systematic Review and Meta-Analysis of Acute Mortality and Complication Rates Following Leadless Pacemaker Placement Using National-Level Data.Medicina (Kaunas, Lithuania) · 2025Pooled it
- Comparison of Postoperative Outcomes between Leadless and Conventional Transvenous Pacemakers Implantation: An Up-to-Date Meta-analysis.Reviews in cardiovascular medicine · 2024Pooled it
- The Effectiveness and Safety of Leadless Pacemakers: An Updated Meta-Analysis.Current cardiology reports · 2024Pooled it
- Two-year outcomes of leadless vs. transvenous single-chamber ventricular pacemaker in high-risk subgroups.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023Trial
- Impact of Leadless Pacemaker Implantation Position on Subclinical Right Ventricular Perforation.Pacing and clinical electrophysiology : PACE · 2026Article
- Diagnostic and Management Challenges in a Non-Infectious Pacemaker Pocket Swelling: A Case Report and Literature Review.Diagnostics (Basel, Switzerland) · 2026Article
- Cardiac implantable electronic devices in heart failure: needs, challenges, and real-world implementation.Heart failure reviews · 2026Review
- Comparison of Outcomes of Leadless Versus Transvenous Pacemakers Following Tricuspid Valve Surgery.Journal of the American Heart Association · 2026Article
- Leadless pacemaker tine fracture resulting in device migration to the pulmonary artery: A case report.Journal of cardiology cases · 2026Article
- Tricuspid Regurgitation After Leadless Pacemaker Implantation: The Role of Atrioventricular Synchrony.Clinical cardiology · 2026Review
- Computational analysis of intracardiac collision risk and optimal site for right ventricular leadless left bundle branch area pacing: A simulation study.Heart rhythm O2 · 2026Article
- Leadless atrial versus transvenous pacing for sinus node dysfunction: 1-year outcomes from the leadless ARRIVE real-world study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026Article
- Safety and efficacy of leadless pacemakers: A systematic review and meta-analysis.Heart rhythm O2 · 2026Review
- Safety of leadless versus transvenous pacemakers in patients with low body surface area: a matched-pair analysis.BMC cardiovascular disorders · 2026Article
- Safety and efficacy of completely transthoracic echocardiography guided leadless pacemaker implantation assisted by Panna guide wire: initial clinical experience.Frontiers in cardiovascular medicine · 2026Article
- Global Research Trends and Hotspots in Cardiac Devices: A Bibliometric and Visual Analysis.Healthcare (Basel, Switzerland) · 2025Review
- Leadless Versus Transvenous Single-Chamber Ventricular Pacemakers: Real-World Evidence From Aveir VR Coverage With Evidence Development Study.Journal of the American Heart Association · 2025Observational
- Long-term follow up of single-chamber atrial pacing-system upgrade and Wenckebach block point behavior: potential implications for leadless AAI pacing?Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2025Article
- Comparison of readmission outcomes and complications between leadless and traditional transvenous pacemakers in older adults: a nationwide readmission analysis of 49852 admission events.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025Article
- Successful implantation of a leadless pacemaker in a patient after tricuspid valve replacement following cardiac tumor removal: a case report and literature review.BMC cardiovascular disorders · 2025Review
3 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Erratum issued
Authors and funding
9 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: The safety and efficacy of leadless VVI pacemakers have been demonstrated in multiple clinical trials, but the comparative performance of the device in a large, real-world population has not been examined. Objective: To compare patient characteristics and complications among patients implanted with leadless VVI and transvenous VVI pacemakers. Design, Setting, Participants: The Longitudinal Coverage With Evidence Development Study on Micra Leadless Pacemakers (Micra CED) is a continuously enrolling observational cohort study evaluating complications, utilization, and outcomes of leadless VVI pacemakers in the US Medicare fee-for-service population. Patients implanted between March 9, 2017, and December 1, 2018, were identified and included. All Medicare patients implanted with leadless VVI and transvenous VVI pacemakers during the study period were enrolled. Patients with less than 12 months of continuous enrollment in Medicare prior to leadless VVI or transvenous VVI implant and with evidence of a prior cardiovascular implantable electronic device were excluded, leaving 5746 patients with leadless VVI pacemakers and 9662 patients with transvenous VVI pacemakers. Data were analyzed from May 2018 to April 2021. Exposures: Medicare patients implanted with leadless VVI pacemakers or transvenous VVI pacemakers. Main Outcomes and Measures: The main outcomes were acute (30-day) complications and 6-month complications. Results: Of 15 408 patients, 6701 (43.5%) were female, and the mean (SD) age was 81.0 (8.7) years. Compared with patients with transvenous VVI pacemakers, patients with leadless VVI pacemakers were more likely to have end-stage kidney disease (690 [12.0%] vs 226 [2.3%]; P < .001) and a higher mean (SD) Charlson Comorbidity Index score (5.1 [3.4] vs 4.6 [3.0]; P < .001). The unadjusted acute complication rate was higher in patients with leadless VVI pacemakers relative to transvenous VVI pacemakers (484 of 5746 [8.4%] vs 707 of 9662 [7.3%]; P = .02). However, there was no significant difference in overall acute complication rates following adjustment for patient characteristics (7.7% vs 7.4%; risk difference, 0.3; 95% CI, -0.6 to 1.3; P = .49). Pericardial effusion and/or perforation within 30 days was significantly higher among patients with leadless VVI pacemakers compared with patients with transvenous VVI pacemakers in both unadjusted and adjusted models (unadjusted, 47 of 5746 [0.8%] vs 38 of 9662 [0.4%]; P < .001; adjusted, 0.8% vs 0.4%; risk difference, 0.4; 95% CI, 0.1 to 0.7; P = .004). Patients implanted with leadless VVI pacemakers had a lower rate of 6-month complications compared with patients implanted with transvenous VVI pacemakers (unadjusted hazard ratio, 0.84; 95% CI, 0.68-1.03; P = .10; adjusted hazard ratio, 0.77; 95% CI, 0.62-0.96; P = .02). Conclusions and Relevance: In this study, despite significant differences in patient characteristics, patients in whom a leadless pacemaker was implanted were observed to have higher rates of pericardial effusion and/or perforation but lower rates of other device-related complications and requirements for device revision at 6 months. Understanding the benefits and risks associated with leadless VVI pacemakers compared with transvenous VVI pacemakers can help clinicians and patients make informed treatment decisions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.