Evidence map›Paper›PMID 34318215›Full record

ArticleJTCVS techniques2021

Aortic annuloplasty: Subcommissural, intra-annular suture techniques, external and internal rings.

Jan M Federspiel, Tristan Ehrlich, Karen Abeln, Hans-Joachim Schäfers

Open access · goldAbstract readEditorial
In one paragraph

Article in JTCVS techniques, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
3.0field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 31 citations in OpenAlex.

  1. Aortic valve repair with annuloplasty.Interdisciplinary cardiovascular and thoracic surgery · 2025
    Article
  2. Aortic regurgitation: from mechanisms to management.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2024
    Review
  3. Article
  4. Adjustable external Dacron annuloplasty in aortic valve repair.General thoracic and cardiovascular surgery · 2024
    Article
  5. Review
  6. Remodeling of the aortic root-a 28-year journey.Annals of cardiothoracic surgery · 2023
    Article
  7. Recent innovations in aortic valve surgery: True progress?Turk gogus kalp damar cerrahisi dergisi · 2023
    Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Jan M FederspielDepartment of Thoracic and Cardiovascular Surgery, Saarland University Medical Center, Homburg/Saar, Germany.
Tristan EhrlichDepartment of Thoracic and Cardiovascular Surgery, Saarland University Medical Center, Homburg/Saar, Germany.
Karen AbelnDepartment of Thoracic and Cardiovascular Surgery, Saarland University Medical Center, Homburg/Saar, Germany.
Hans-Joachim SchäfersDepartment of Thoracic and Cardiovascular Surgery, Saarland University Medical Center, Homburg/Saar, Germany.
Saarland University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aortic valve repair and valve-preserving root replacement have evolved into increasingly practiced procedures. With increasing experience, the need for an annuloplasty has become more evident, at least for pathologies that involve annular dilatation. To understand the effect of an aortic annuloplasty, it is necessary to know the details of aortic valve and root anatomy. Geometrically, the functional annulus is best defined as the virtual basal ring, ie, plane of the cusp nadirs. The sinotubular diameter also influences the aortic valve form, at least in tricuspid valves. Different annuloplasty concepts have been developed for isolated valve repair or in combination with root remodeling, such as subcommissural sutures, suture annuloplasty, external, and internal rings. Subcommissural sutures do not consistently provide durable annular stabilization. More positive results have been published for circular approaches, ie, suture annuloplasty, external, or internal rings. The results of different techniques are difficult to judge because most outcome data have not been analyzed with control of confounding predictors of repair failure. The evidence that annuloplasty improves aortic valve function and repair durability is best documented for isolated bicuspid aortic valve repair. In summary, the addition of annuloplasty to aortic valve reconstruction is probably a useful tool to improve valve competence and stabilize the repair. This is best documented for isolated bicuspid valve repair and circular approaches. The relative benefit of individual concepts is difficult to judge because of lack of both control groups and control of confounding factors.

Indexed as

annuloplastyaortic valveaortic valve reconstruction

Identifiers

PMID34318215
PMCPMC8311589
OpenAlexW3123018913

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.