Evidence map›Paper›PMID 34315770›Full record

ArticleBMJ (Clinical research ed.)2021

Diagnostic accuracy of rapid antigen tests in asymptomatic and presymptomatic close contacts of individuals with confirmed SARS-CoV-2 infection: cross sectional study.

Ewoud Schuit, Irene K Veldhuijzen, Roderick P Venekamp, Wouter van den Bijllaardt, Suzan D Pas, Esther B Lodder, Richard Molenkamp, Corine H GeurtsvanKessel, Jans Velzing, Robin C Huisman and 8 more

Open access · bronzeAbstract read
In one paragraph

Article in BMJ (Clinical research ed.), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 52 papers, 5 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
52citing papers in PubMed, 5 pooled it
6.2field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

52 citing papers in PubMed, 5 syntheses or guidelines pooled it, 99 citations in OpenAlex.

  1. Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection.The Cochrane database of systematic reviews · 2025
    Pooled it
  2. Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection.The Cochrane database of systematic reviews · 2022
    Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Trial
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Diagnostic accuracy of SARS-CoV-2 rapid antigen self-tests in asymptomatic individuals in the omicron period: a cross-sectional study.Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases · 2023
    Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors at 7 institutions in 2 countries.

Ewoud SchuitJulius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands.ORCID https://orcid.org/0000-0002-9548-3214
Irene K VeldhuijzenCentre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, Netherlands.ORCID https://orcid.org/0000-0002-3132-4070
Roderick P VenekampJulius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands.ORCID https://orcid.org/0000-0002-1446-9614
Wouter van den BijllaardtMicrovida Laboratory for Medical Microbiology, Amphia Hospital, Breda, Netherlands.ORCID https://orcid.org/0000-0003-0676-2594
Suzan D PasMicrovida Laboratory for Medical Microbiology, Amphia Hospital, Breda, Netherlands.ORCID https://orcid.org/0000-0003-1943-1217
Esther B LodderPublic Health Service West-Brabant, Breda, Netherlands.
Richard MolenkampDepartment of Viroscience, Erasmus MC, Rotterdam, Netherlands.ORCID https://orcid.org/0000-0002-9004-3850
Corine H GeurtsvanKesselDepartment of Viroscience, Erasmus MC, Rotterdam, Netherlands.ORCID https://orcid.org/0000-0002-7678-314X
Jans VelzingDepartment of Viroscience, Erasmus MC, Rotterdam, Netherlands.ORCID https://orcid.org/0000-0001-9304-742X
Robin C HuismanDepartment of Viroscience, Erasmus MC, Rotterdam, Netherlands.
Lieke BrouwerPublic Health Service Rotterdam-Rijnmond, Rotterdam, Netherlands.ORCID https://orcid.org/0000-0003-3616-9070
Timo L BoelsumsPublic Health Service Rotterdam-Rijnmond, Rotterdam, Netherlands.ORCID https://orcid.org/0000-0002-8406-2916
Gregorius J SipsCentre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, Netherlands.ORCID https://orcid.org/0000-0003-4506-983X
Kimberly S M BenschopCentre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, Netherlands.ORCID https://orcid.org/0000-0002-8328-0882
Lotty HooftJulius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands.ORCID https://orcid.org/0000-0002-7950-2980
Janneke H H M van de WijgertJulius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands.ORCID https://orcid.org/0000-0003-2728-4560
Susan van den HofCentre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, Netherlands.ORCID https://orcid.org/0000-0002-2968-9652
Karel G M MoonsJulius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands k.g.m.moons@umcutrecht.nl.ORCID https://orcid.org/0000-0003-2118-004X
Erasmus MC · NLUtrecht University · NLGGD Rotterdam-Rijnmond · NLNational Institute for Public Health and the Environment · NLAmphia Ziekenhuis · NLGGD West-Brabant · NLUniversity of Liverpool · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo assess the diagnostic test accuracy of two rapid antigen tests in asymptomatic and presymptomatic close contacts of people with SARS-CoV-2 infection on day 5 after exposure.

designProspective cross sectional study.

settingFour public health service covid-19 test sites in the Netherlands.

participants4274 consecutively included close contacts (identified through test-and-trace programme or contact tracing app) aged 16 years or older and asymptomatic for covid-19 when requesting a test.

main outcome measuresSensitivity, specificity, and positive and negative predictive values of Veritor System (Beckton Dickinson) and Biosensor (Roche Diagnostics) rapid antigen tests, with reverse-transcriptase polymerase chain reaction (RT-PCR) testing as reference standard. The viral load cut-off above which 95% of people with a positive RT-PCR test result were virus culture positive was used as a proxy of infectiousness.

resultsOf 2678 participants tested with Veritor, 233 (8.7%) had a RT-PCR confirmed SARS-CoV-2 infection of whom 149 were also detected by the rapid antigen test (sensitivity 63.9%, 95% confidence interval 57.4% to 70.1%). Of 1596 participants tested with Biosensor, 132 (8.3%) had a RT-PCR confirmed SARS-CoV-2 infection of whom 83 were detected by the rapid antigen test (sensitivity 62.9%, 54.0% to 71.1%). In those who were still asymptomatic at the time of sampling, sensitivity was 58.7% (51.1% to 66.0%) for Veritor (n=2317) and 59.4% (49.2% to 69.1%) for Biosensor (n=1414), and in those who developed symptoms were 84.2% (68.7% to 94.0%; n=219) for Veritor and 73.3% (54.1% to 87.7%; n=158) for Biosensor. When a viral load cut-off was applied for infectiouness (≥5.2 log10 SARS-CoV-2 E gene copies/mL), the overall sensitivity was 90.1% (84.2% to 94.4%) for Veritor and 86.8% (78.1% to 93.0%) for Biosensor, and 88.1% (80.5% to 93.5%) for Veritor and 85.1% (74.3% to 92.6%) for Biosensor, among those who remained asymptomatic throughout. Specificities were >99%, and positive and negative predictive values were >90% and >95%, for both rapid antigen tests in all analyses.

conclusionsThe sensitivities of both rapid antigen tests in asymptomatic and presymptomatic close contacts tested on day 5 onwards after close contact with an index case were more than 60%, increasing to more than 85% after a viral load cut-off was applied as a proxy for infectiousness.

Identifiers

PMID34315770
PMCPMC8314145
OpenAlexW3185751529

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.