Evidence map›Paper›PMID 34313710›Full record

ArticleTranslational vision science & technology2021

Depth-resolved Corneal Biomechanical Changes Measured Via Optical Coherence Elastography Following Corneal Crosslinking.

Tanner J Ferguson, Srinidhi Singuri, Sanjai Jalaj, Matthew R Ford, Vinicius S De Stefano, Ibrahim Seven, William J Dupps

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Review
  3. [Controllability and predictability of riboflavin-ultraviolet A collagen cross-linking: advances in experimental techniques and theoretical research].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Review
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Tanner J FergusonCole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Srinidhi SinguriDepartment of Ophthalmology, Cleveland Clinic Lerner College of Medicine of CWRU, Cleveland, Ohio, USA.
Sanjai JalajCole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Matthew R FordCole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Vinicius S De StefanoCole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Ibrahim SevenCole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA.
William J DuppsCole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Cleveland Clinic · USCleveland Eye Clinic · USCase Western Reserve University · USCleveland Clinic Lerner College of Medicine · US

Funding

RESOURCE/SERVICE CORE C - MOLECULAR INFORMATICS MODULEP30EY025585 · NEI · CLEVELAND CLINIC LERNER COM-CWRU · PI Brian D Perkins · 2016 to 2026
$7.7M
Corneal Elastography and Patient-Specific Modeling for Simulation-based TherapyR01EY023381 · NEI · CLEVELAND CLINIC LERNER COM-CWRU · PI DUPPS, WILLIAM JOSEPH · 2013 to 2017
$2.0M
NEI NIH HHS P30 EY025585NEI NIH HHS R01 EY023381
6 · The paper itself

Abstract

Purpose: To evaluate depth-resolved changes of corneal biomechanical properties in eyes with corneal ectasia after corneal crosslinking (CXL) using optical coherence elastography. Methods: In a prospective pilot series of eyes with corneal ectasia, a custom high-speed swept source optical coherence tomography system was used to image the cornea before and 3 months after CXL during a low-speed applanating deformation while monitoring applanation force. Cross-correlation was applied to track frame-by-frame two-dimensional optical coherence tomography speckle displacements, and the slope of force versus local axial displacement behavior during the deformation was used to produce a two-dimensional array of axial stiffness (k). These values were averaged for anterior (ka) and posterior (kp) stromal regions and expressed as a ratio (ka/kp) to assess depth-dependent differences in stiffness. CXL was performed according to the Dresden protocol with a system approved by the U.S. Food and Drug Administration. Results: Four eyes from four patients with keratoconus (n = 3) or post-LASIK ectasia (n = 1) underwent optical coherence elastography before and 3 months after CXL. The mean ka/kp was 1.03 ± 0.07 before CXL compared with 1.34 ± 0.17 after the CXL procedure. All four eyes demonstrated at least a 20% increase in the ka/kp. Conclusions: Preferential stiffening of the anterior stroma with the standard CXL protocol was demonstrated with optical coherence elastography in live human subjects. Translational Relevance: Although ex vivo studies have demonstrated anterior stiffening effects after CXL using various destructive and nondestructive methods, this report presents the first evidence of such changes in serial live human measurements.

Indexed as

Elasticity Imaging TechniquesKeratoconusCorneaCross-Linking ReagentsHumansPhotosensitizing AgentsProspective StudiesUnited StatesCross-Linking ReagentsPhotosensitizing Agents

Identifiers

PMID34313710
PMCPMC8322708
OpenAlexW3184225299

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked