Reduction of cardiac motion artifact in step-and-shoot coronary CT angiography with third-generation as compared with second-generation dual-source CT scanners.

Liang Jin, Ji'an Zhou, Yiyi Gao, Wei Zhao, Ming Li, Zhizhong Wang

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Diagnostic and interventional radiology (Ankara, Turkey), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Liang JinDepartment of Radiology, Huadong Hospital, affiliated to Fudan University, Shanghai, China.
Ji'an ZhouDepartment of Medicine, Huadong Hospital, affiliated to Fudan University, Shanghai, China.
Yiyi GaoDepartment of Radiology, Huadong Hospital, affiliated to Fudan University, Shanghai, China.
Wei ZhaoDepartment of Radiology, Huadong Hospital, affiliated to Fudan University, Shanghai, China.
Ming LiDepartment of Radiology, Huadong Hospital, affiliated to Fudan University, Shanghai, China;Institute of Functional and Molecular Medical Imaging,Fudan University, Shanghai, China.
Zhizhong WangCaoxian People's Hospital, Shandong, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe aimed to compare the effects of misregistration (stair-step artifact) occurrence during coronary computed tomography angiography (CCTA) using third- and second-generation dual-source computed tomography (DSCT) scanners. METHODSÇ: CCTA was performed in consecutive patients with suspected coronary heart disease. Patients were randomly assigned to two groups and imaged using a third-generation (n=68; group A) or second-generation (n=63; group B) DSCT scanner. Heart rate (HR), heart rate variability (HRV), the number of acquisition steps required, and the anatomical cardiac length of each patient were recorded and compared between the two groups. Qualitative interpretation and analyses were scored with respect to subjective image quality and misregistration (stair-step artifact) by two interpreters. Cohen's kappa was used to evaluate the consistency between the observers.

resultsAll CCTA images (100%) on both DSCT scanners yielded satisfactory image quality, with a subjective image quality score of 4.21±0.17. The consistency between the two observers with respect to misregistration and subjective scores were good (κ= 0.91 and 0.92, respectively). Both the number of acquisition steps required and the scan length of each patient in group A differed significantly (p < 0.001) from those in group B; there were significantly fewer artifacts in group A than in group B (p < 0.001). Misregistration artifacts did not correlate with the HRs or HRVs between two required acquisition steps (p > 0.20).

conclusionAs compared with second-generation DSCT, the reduced number of acquisition steps required and the shorter scan length in third-generation DSCT reduced the occurrence of misregistration artifacts in CCTA images.

Indexed as

ArtifactsComputed Tomography AngiographyCoronary AngiographyHumansRadiation DosageTomography, X-Ray Computed

Identifiers

PMID34313232
PMCPMC8289436

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.