Evidence map›Paper›PMID 34309708›Full record

ArticleClinical neuroradiology2022

Flow Redirection Endoluminal Device (FRED) with or without Adjunctive Coiling in Treatment of Very Large and Giant Cerebral Aneurysms.

Sedat Giray Kandemirli, Feyyaz Baltacioglu, Jessica Jesser, Osman Kizilkilic, Civan Islak, Markus Möhlenbruch, Naci Kocer

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical neuroradiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 2 pooled it
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 2 syntheses or guidelines pooled it, 13 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 3 countries.

Sedat Giray KandemirliDepartment of Radiology, University of Iowa Hospital and Clinics, Iowa City, USA.
Feyyaz BaltaciogluDepartment of Radiology, Marmara University School of Medicine, Istanbul, Turkey.
Jessica JesserDepartment of Neuroradiology, University of Heidelberg, Heidelberg, Germany.
Osman KizilkilicDepartment of Radiology, Division of Neuroradiology, Cerrahpasa Medical Faculty, Istanbul, Turkey.
Civan IslakDepartment of Radiology, Division of Neuroradiology, Cerrahpasa Medical Faculty, Istanbul, Turkey.
Markus MöhlenbruchDepartment of Neuroradiology, University of Heidelberg, Heidelberg, Germany.
Naci KocerDepartment of Radiology, Division of Neuroradiology, Cerrahpasa Medical Faculty, Istanbul, Turkey. nkocer@istanbul.edu.tr.
Istanbul University-Cerrahpaşa · TRHeidelberg University · DEAmerikan Hastanesi · TRUniversity of Iowa Hospitals and Clinics · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeFlow diverter stents are gaining wider use in the treatment of complex intracranial aneurysms; however, there are limited data on occlusion and complication rates of flow diverters in very large and giant aneurysms. This study assessed the safety and efficacy of flow redirection endoluminal device (FRED) and FRED Jr. stents in aneurysms ≥ 20 mm.

methodsWe retrospectively analyzed all aneurysms ≥ 20 mm treated with FRED/FRED Jr. between January 2010 and June 2020 from three centers. Endpoints for clinical safety were absence of major stroke, aneurysmal rupture, or death and complete or near-complete occlusion for efficacy.

resultsA total of 45 patients with very large (28 cases) and giant aneurysms (17 cases) were treated with FRED (41 cases), and FRED Jr. (4 cases) stents. The majority of the aneurysms (40/45, 88.9%) were in the anterior circulation. Adjunctive aneurysm coiling was performed in 21 aneurysms (46.7%). Technical complications were encountered in 4 procedures (8.9%). Ischemic and hemorrhagic complication rates were 6.7% and 8.9%, respectively. There was no case with major stroke. The mortality rate was 8.9%, and all cases were due to hemorrhagic complications from aneurysmal rupture. Median angiographic follow-up was 21.5 months (range 3-60 months). Complete occlusion was achieved in 32 aneurysms (71.1%), and near-complete occlusion in 5 cases (11.1%).

conclusionThe use of FRED/FRED Jr. for the treatment of aneurysms ≥ 20 mm achieved a long-term aneurysm occlusion rate and a safety profile comparable to the large series reported with other flow diverter stents.

Indexed as

Aneurysm, RupturedEmbolization, TherapeuticEndovascular ProceduresIntracranial AneurysmStrokeHumansRetrospective StudiesStentsTreatment OutcomeComplicationEndovascularFlow diverterLong-termOcclusion

Identifiers

PMID34309708
OpenAlexW3186730634

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.