Evidence map›Paper›PMID 34307922›Full record

ArticlePhysics and imaging in radiation oncology2021

Patient position verification in magnetic-resonance imaging only radiotherapy of anal and rectal cancers.

David Bird, Matthew Beasley, Michael G Nix, Marcus Tyyger, Hazel McCallum, Mark Teo, Alexandra Gilbert, Nathalie Casanova, Rachel Cooper, David L Buckley and 4 more

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

David BirdLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Matthew BeasleyLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Michael G NixLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Marcus TyygerLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Hazel McCallumNorthern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, UK.
Mark TeoLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Alexandra GilbertLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Nathalie CasanovaLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Rachel CooperLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
David L BuckleyBiomedical Imaging, University of Leeds, Leeds, UK.
David Sebag-MontefioreLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Richard SpeightLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Ann M HenryLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Bashar Al-QaisiehLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.

Funding

Cancer Research UK 28301
6 · The paper itself

Abstract

background and purposeMagnetic resonance (MR)-only treatment pathways require either the MR-simulation or synthetic-computed tomography (sCT) as an alternative reference image for cone beam computed tomography (CBCT) patient position verification. This study assessed whether using T2 MR or sCT as CBCT reference images introduces systematic registration errors as compared to CT for anal and rectal cancers. MATERIALS AND

methodsA total of 32 patients (18 rectum,14 anus) received pre-treatment CT- and T2 MR- simulation. Routine treatment CBCTs were acquired. sCTs were generated using a validated research model. The local clinical registration protocol, using a grey-scale registration algorithm, was performed for 216 CBCTs using CT, MR and sCT as the reference image. Linear mixed effects modelling identified systematic differences between modalities.

resultsSystematic translation and rotation differences to CT for MR were -0.3 to + 0.3 mm and -0.1 to 0.4° for anal cancers and -0.4 to 0.0 mm and 0.0 to 0.1° for rectal cancers, and for sCT were -0.4 to + 0.8 mm, -0.1 to 0.2° for anal cancers and -0.6 to + 0.2 mm, -0.1 to + 0.1° for rectal cancers.

conclusionsT2 MR or sCT can successfully be used as reference images for anal and rectal cancer CBCT position verification with systematic differences to CT <±1 mm and <±0.5°. Clinical enabling of alternative modalities as reference images by vendors is required to reduce challenges associated with their use.

Indexed as

Anal cancerCBCTCBCT patient positioningMRI-onlyMR-onlyRectal cancer

Identifiers

PMID34307922
PMCPMC8295842

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.