Evidence map›Paper›PMID 34304321›Full record

ArticleVisual computing for industry, biomedicine, and art2021

Quantitative evaluation of deep convolutional neural network-based image denoising for low-dose computed tomography.

Keisuke Usui, Koichi Ogawa, Masami Goto, Yasuaki Sakano, Shinsuke Kyougoku, Hiroyuki Daida

Abstract read
In one paragraph

Article in Visual computing for industry, biomedicine, and art, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Keisuke UsuiDepartment of Radiological Technology, Faculty of Health Science, Juntendo University, Tokyo, 113-8421, Japan. k-usui@juntendo.ac.jp.
Koichi OgawaFaculty of Science and Engineering, Hosei University, Tokyo, 184-8584, Japan.
Masami GotoDepartment of Radiological Technology, Faculty of Health Science, Juntendo University, Tokyo, 113-8421, Japan.
Yasuaki SakanoDepartment of Radiological Technology, Faculty of Health Science, Juntendo University, Tokyo, 113-8421, Japan.
Shinsuke KyougokuDepartment of Radiological Technology, Faculty of Health Science, Juntendo University, Tokyo, 113-8421, Japan.
Hiroyuki DaidaDepartment of Radiological Technology, Faculty of Health Science, Juntendo University, Tokyo, 113-8421, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To minimize radiation risk, dose reduction is important in the diagnostic and therapeutic applications of computed tomography (CT). However, image noise degrades image quality owing to the reduced X-ray dose and a possible unacceptably reduced diagnostic performance. Deep learning approaches with convolutional neural networks (CNNs) have been proposed for natural image denoising; however, these approaches might introduce image blurring or loss of original gradients. The aim of this study was to compare the dose-dependent properties of a CNN-based denoising method for low-dose CT with those of other noise-reduction methods on unique CT noise-simulation images. To simulate a low-dose CT image, a Poisson noise distribution was introduced to normal-dose images while convoluting the CT unit-specific modulation transfer function. An abdominal CT of 100 images obtained from a public database was adopted, and simulated dose-reduction images were created from the original dose at equal 10-step dose-reduction intervals with a final dose of 1/100. These images were denoised using the denoising network structure of CNN (DnCNN) as the general CNN model and for transfer learning. To evaluate the image quality, image similarities determined by the structural similarity index (SSIM) and peak signal-to-noise ratio (PSNR) were calculated for the denoised images. Significantly better denoising, in terms of SSIM and PSNR, was achieved by the DnCNN than by other image denoising methods, especially at the ultra-low-dose levels used to generate the 10% and 5% dose-equivalent images. Moreover, the developed CNN model can eliminate noise and maintain image sharpness at these dose levels and improve SSIM by approximately 10% from that of the original method. In contrast, under small dose-reduction conditions, this model also led to excessive smoothing of the images. In quantitative evaluations, the CNN denoising method improved the low-dose CT and prevented over-smoothing by tailoring the CNN model.

Indexed as

Convolutional neural networkDeep learningDenoisingImage qualityLow-dose computed tomography

Identifiers

PMID34304321
PMCPMC8310822

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.