ArticleScientific reports2021
Influence of frosted haptics on rotational stability of toric intraocular lenses.
Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed.
- Reproducibility of the Magnitude of Lens Rotation Following Implantation of a Toric Intraocular Lens with Modified Haptics.Clinical ophthalmology (Auckland, N.Z.) · 2022Trial
- Rotational Stability of the Clareon PanOptix Toric (CNWTTx) Hydrophobic Multifocal IOL: Real-World Clinical Outcomes.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Patient-Reported Outcomes After Bilateral Implantation of Monofocal versus Monofocal-Plus Toric Intraocular Lenses.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Misalignment After Implantation of One-Piece Hydrophobic Toric Intraocular Lenses: Comparison Among Manufacturers and Generations.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Clinical and Patient-Reported Outcomes of Premium Intraocular Lenses in Glaucoma Patients Undergoing Combined Cataract and Minimally Invasive Glaucoma Surgery.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Clinical impact of intraocular lens tilt and decentration: a cross-sectional study.BMC ophthalmology · 2025Article
- Study on Factors Affecting Toric Intraocular Lens Rotation Using Intraoperative OCT-Factors Influencing IOL Deployment and Proximity to Posterior Capsule After Insertion.Journal of clinical medicine · 2025Article
- Comparing Rotational Stability of Clareon and Eyhance Toric IOLs in a Real-World Setting.Clinical ophthalmology (Auckland, N.Z.) · 2025Article
- Rotational Stability and Subjective Results of Tecnis Eyhance Toric II Intraocular Lens.Clinical ophthalmology (Auckland, N.Z.) · 2025Article
- Comparison of visual efficacy and patient's satisfaction between two toric IOLs, enhanced for intermediate vision and monofocal.BMC ophthalmology · 2024Article
- Rotational stability of monofocal and diffractive multifocal toric intraocular lens with identical design and material: a propensity score based prospective comparative study.BMC ophthalmology · 2024Article
- Insights into the rotational stability of toric intraocular lens implantation: diagnostic approaches, influencing factors and intervention strategies.Frontiers in medicine · 2024Review
- Extensive misalignment of plate-haptic rotationally asymmetric multifocal toric intraocular lens.Japanese journal of ophthalmology · 2023Article
- Influence of decentration of plate-haptic toric intraocular lens on postoperative visual quality.BMC ophthalmology · 2023Article
- Temperature-controlled porcine eye holder for observing intraocular temperature during cataract surgery.Scientific reports · 2023Article
- Biomedical Silicones: Leveraging Additive Strategies to Propel Modern Utility.ACS macro letters · 2023Article
- Repositioning Rates of Toric IOLs Implanted in Cataract Surgery Patients: A Retrospective Chart Review.Clinical ophthalmology (Auckland, N.Z.) · 2023Article
- One-year long-term clinical outcomes following diffractive trifocal toric intraocular lens implantation: retrospective observational case series study.Annals of translational medicine · 2022Article
- Long-term outcomes of cataract surgery with toric intraocular lens implantation by the type of preoperative astigmatism.Scientific reports · 2022Article
- Post-Market Evaluation of Rotational Stability and Visual Performance of a New Toric Intraocular Lens with Frosted Haptics.Clinical ophthalmology (Auckland, N.Z.) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We investigated the unfolding property and rotational stability of a new toric intraocular lens (IOL); TECNIS toric II (toric-II, ZCW, Johnson & Johnson) that is an improved version of TECNIS toric IOL (toric-I, ZCV). Both IOLs are based on an identical platform, except for the frosted haptics with toric-II IOL. The study consisted of two parts; experimental study and clinical, retrospective, case series. Experimental study indicated that the overall time from IOL ejection to unfolding to 11 mm was significantly shorter with toricII than toric-I IOLs (p = 0.032), due to the earlier separation of the haptics from the optic with toric-II IOL. Clinical study included 131 eyes of 99 patients who had undergone phacoemulsification and toric IOL implantation. At 3 months postoperatively, toric-II IOL showed significantly better rotational stability than toric-I IOL, including smaller residual manifest astigmatism (p = 0.018), less amount of axis misalignment from the intended axis (p = 0.04), lower incidence of misalignment > 10º (p = 0.0044), and less degree of prediction errors (p = 0.043). Postoperative uncorrected distance visual acuity tended to be better in the toric-II than in the toric-I groups, with marginal statistical difference (p = 0.057). TECNIS toric II IOL with the frosted haptics showed significantly better rotational stability than its predecessor, probably due to quicker unfolding and greater friction with the capsular bag.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials