Evidence map›Paper›PMID 34300724›Full record

ArticleMaterials (Basel, Switzerland)2021

In Vitro Analysis of Wearing of Hip Joint Prostheses Composed of Different Contact Materials.

Jian Su, Jian-Jun Wang, Shi-Tong Yan, Min Zhang, Hui-Zhi Wang, Ning-Ze Zhang, Yi-Chao Luan, Cheng-Kung Cheng

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jian SuSchool of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China.
Jian-Jun WangBeijing Institute of Medical Device Testing, Beijing 101111, China.
Shi-Tong YanBeijing Institute of Medical Device Testing, Beijing 101111, China.
Min ZhangBeijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100083, China.
Hui-Zhi WangSchool of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
Ning-Ze ZhangSchool of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China.
Yi-Chao LuanSchool of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China.
Cheng-Kung ChengSchool of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China.ORCID 0000-0002-2167-6873

Funding

the National Key Research and Development Projects Grant number: 2016YFC1101904
6 · The paper itself

Abstract

Cobalt-chromium-molybdenum alloy (CoCrMo) and ceramic are the two most common materials for the femoral head in hip joint prostheses, and the acetabular liner is typically made from ultra-high molecular weight polyethylene (UHMWPE), highly cross-linked polyethylene (XLPE), or highly cross-linked polyethylene blended with Vitamin E (VEXLPE). The selection of suitable materials should consider both wear performance and cost-effectiveness. This study compared the wear rate between different friction pairs using a hip joint simulator and then recommended a suitable prosthesis based on the corresponding processing technology and cost. All wear simulations were performed in accordance with ISO 14242, using the same hip joint simulator and same test conditions. This study found that when using the same material for the femoral head, the XLPE and VEXLPE liners had a lower wear rate than the UHMWPE liners, and the wear rate of the XLPE liners increased after blending with Vitamin E (VEXLPE). There was no significant difference in the wear rate of XLPE when using a CoCrMo or ceramic head. Considering the wear rate and cost-effectiveness, a CoCrMo femoral head with an accompanying XLPE liner is recommended as the more suitable combination for hip prostheses.

Indexed as

acetabular linerfemoral headhip prosthesiswear rateXLPE

Identifiers

PMID34300724
PMCPMC8305543

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.