Evidence map›Paper›PMID 34300644›Full record

ArticleSensors (Basel, Switzerland)2021

Highly Sensitive Electrochemical Sensor for Diagnosis of Diabetic Ketoacidosis (DKA) by Measuring Ketone Bodies in Urine.

Anna Go, Sung Ryul Park, Yejin Ku, Mingge Sun, Sangho Yeon, Jin-Kyun Lee, Sang Wook Lee, Min-Ho Lee

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Nanowire Array Breath Acetone Sensor for Diabetes Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  6. Review
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Anna GoSchool of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Korea.
Sung Ryul ParkSchool of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Korea.
Yejin KuProgram in Environmental and Polymer Engineering, Department of Polymer Science and Engineering, Inha University, 100 Inha-Ro, Nam-Gu, Incheon 22212, Korea.
Mingge SunSchool of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Korea.
Sangho YeonSchool of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Korea.
Jin-Kyun LeeProgram in Environmental and Polymer Engineering, Department of Polymer Science and Engineering, Inha University, 100 Inha-Ro, Nam-Gu, Incheon 22212, Korea.
Sang Wook LeeBio-Health Product Research Center, Inje University, Gimhae-si 50834, Korea.
Min-Ho LeeSchool of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Korea.ORCID 0000-0002-7028-4745

Funding

Chung-Ang University Young Scientist Scholarship 2019Ministry of Environment 1485016394
6 · The paper itself

Abstract

In this report, we present an enzyme deposited Au electrode for an electrochemical measurement of acetylacetic acid (AcAc) in urine. The electrode has an immobilized layer of a mixture of D-β-hydroxybutyrate dehydrogenase (HBDH) and nicotinamide adenine dinucleotide (NADH) as sensing material to investigate its electroanalytical properties by means of cyclic voltammetry (CV). The modified electrodes are used for the detection of AcAc and present a linear current increase when the AcAc concentration increases. The electrode presents a limit of detection (LOD) of 6.25 mg/dL in the range of 6.25-100 mg/dL for investigation of clinical relevance. Finally, the electrode was evaluated using 20 patient samples. The measured results of urine ketone by the developed electrode were compared with the clinical results from a commercial kit, and the analysis showed good agreement. The proposed electrode was demonstrated to be a very promising platform as a miniaturized electrochemical analyzer for point-of-care monitoring of the critical biochemical parameters such as urine ketone.

Indexed as

Diabetic KetoacidosisKetone BodiesElectrochemical TechniquesElectrodesHumansLimit of DetectionKetone Bodiescyclic voltammetryelectrochemical sensorketone bodynon-invasive detectionpoint of care technology

Identifiers

PMID34300644
PMCPMC8309864

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.