Evidence map›Paper›PMID 34300540›Full record

ArticleSensors (Basel, Switzerland)2021

Accuracy of a Low-Cost 3D-Printed Wearable Goniometer for Measuring Wrist Motion.

Calvin Young, Sarah DeDecker, Drew Anderson, Michele L Oliver, Karen D Gordon

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Calvin YoungSchool of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada.ORCID 0000-0002-4036-4533
Sarah DeDeckerSchool of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada.
Drew AndersonSchool of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada.ORCID 0000-0001-5535-0209
Michele L OliverSchool of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada.
Karen D GordonSchool of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada.ORCID 0000-0002-7894-789X

Funding

Natural Sciences and Engineering Research Council of Canada RGPIN-2019-05009Natural Sciences and Engineering Research Council of Canada RGPIN-2019-05240
6 · The paper itself

Abstract

Wrist motion provides an important metric for disease monitoring and occupational risk assessment. The collection of wrist kinematics in occupational or other real-world environments could augment traditional observational or video-analysis based assessment. We have developed a low-cost 3D printed wearable device, capable of being produced on consumer grade desktop 3D printers. Here we present a preliminary validation of the device against a gold standard optical motion capture system. Data were collected from 10 participants performing a static angle matching task while seated at a desk. The wearable device output was significantly correlated with the optical motion capture system yielding a coefficient of determination (R2) of 0.991 and 0.972 for flexion/extension (FE) and radial/ulnar deviation (RUD) respectively (

Indexed as

Wearable Electronic DevicesWristBiomechanical PhenomenaHumansPrinting, Three-DimensionalRange of Motion, ArticularWrist Jointelectromechanical goniometryoccupational biomechanicswearable device

Identifiers

PMID34300540
PMCPMC8309942

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.