Trial reportPhysics in medicine and biology2021
Saliency-guided deep learning network for automatic tumor bed volume delineation in post-operative breast irradiation.
Trial report in Physics in medicine and biology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- AI in Radiation Oncology: A Comprehensive Review of Current Applications and Future Directions.Cureus · 2025Review
- Auto-segmentation of surgical clips for target volume delineation in post-lumpectomy breast cancer radiotherapy.BMC medical imaging · 2025Article
- Transparency and Representation in Clinical Research Utilizing Artificial Intelligence in Oncology: A Scoping Review.Cancer medicine · 2025Article
- Prior information guided deep-learning model for tumor bed segmentation in breast cancer radiotherapy.BMC medical imaging · 2024Article
- Prior information guided auto-segmentation of clinical target volume of tumor bed in postoperative breast cancer radiotherapy.Radiation oncology (London, England) · 2023Article
- A deep learning approach for automatic delineation of clinical target volume in stereotactic partial breast irradiation (S-PBI).Physics in medicine and biology · 2023Article
- Ensemble learning for glioma patients overall survival prediction using pre-operative MRIs.Physics in medicine and biology · 2022Article
- Improving disease classification performance and explainability of deep learning models in radiology with heatmap generators.Frontiers in radiology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Efficient, reliable and reproducible target volume delineation is a key step in the effective planning of breast radiotherapy. However, post-operative breast target delineation is challenging as the contrast between the tumor bed volume (TBV) and normal breast tissue is relatively low in CT images. In this study, we propose to mimic the marker-guidance procedure in manual target delineation. We developed a saliency-based deep learning segmentation (SDL-Seg) algorithm for accurate TBV segmentation in post-operative breast irradiation. The SDL-Seg algorithm incorporates saliency information in the form of markers' location cues into a U-Net model. The design forces the model to encode the location-related features, which underscores regions with high saliency levels and suppresses low saliency regions. The saliency maps were generated by identifying markers on CT images. Markers' location were then converted to probability maps using a distance transformation coupled with a Gaussian filter. Subsequently, the CT images and the corresponding saliency maps formed a multi-channel input for the SDL-Seg network. Our in-house dataset was comprised of 145 prone CT images from 29 post-operative breast cancer patients, who received 5-fraction partial breast irradiation (PBI) regimen on GammaPod. The 29 patients were randomly split into training (19), validation (5) and test (5) sets. The performance of the proposed method was compared against basic U-Net. Our model achieved mean (standard deviation) of 76.4(±2.7) %, 6.76(±1.83) mm, and 1.9(±0.66) mm for Dice similarity coefficient, 95 percentile Hausdorff distance, and average symmetric surface distance respectively on the test set with computation time of below 11 seconds per one CT volume. SDL-Seg showed superior performance relative to basic U-Net for all the evaluation metrics while preserving low computation cost. The findings demonstrate that SDL-Seg is a promising approach for improving the efficiency and accuracy of the on-line treatment planning procedure of PBI, such as GammaPod based PBI.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.